![Zoom G2.1u Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/zoom/g2-1u/g2-1u_service-manual_938276016.webp)
- -
16
Special Start-up
There are some methods to start up the G2.1u for service.
To start up the unit, set the [POWER] switch to “ON” while holding any keys.
The following table shows which keys are held down.
Keys held down
Purposes
Play Mode
None
Normal operation
Initialization [STORE] Recovering
factory
default
Test Mode
[TYPE +] + [TYPE -] + [RHYTHM]
Function test
Data transfer
[STORE] + [RHYTHM]
Backing up user’s data
Version
[UP]
Checking software version
Revision
[DOWN]
Checking software revision
●
Play Mode
Normal operation.
See the operation manual.
●
Initialization
This startup recovers the factory default condition.
Refer to page 17.
●
Test Mode
This startup is used for the function Test.
Refer to page 13-15.
●
Data transfer
This startup backs up the user’s effect patch data.
Refer to page 11, 12.
●
Version
This startup indicates the software version number.
The indication “0003” appears on the display. (depend on circuit versions)
●
Revision
This startup indicates the software revision number.
The indication “9005” appears on the display. (As of October, 2005)