The 24 patches can be easily selected by
pressing the patch pedals. The right patch
pedal switches to the next patch and the
left patch pedal switches to the previous
patch.

In the initial condition, the 507 is set up
so that the patch pedals select patches
continuously, but you can also set up the
unit so that patches are switched only
within a certain bank of four patches. [For
details, see section 9 Patch Switching
(Application: Bank Hold ON).]

Banks are selected with the VALUE +/-
keys. Press the VALUE+ key to select the
next bank, and the VALUE- key to select
the previous bank.

For example, to switch from Patch 2,
Bank A to Patch 3, Bank C, the patch
pedal would have to be pressed nine
times. Instead, you can press the
VALUE+ key twice to switch to Bank C,
and then press the patch pedal (UP) just
once to select Patch 3.

The effects of the 507 can
be turned off (bypassed)
temporarily, so that only the
original sound of the
instrument is heard. In this
mode, the auto-chromatic
tuning function via the LED
display is also active.

Bypass mode

Pressing both patch pedals
simultaneously activates the
Bypass mode.

To cancel the Bypass mode, simply press one of the patch pedals. The unit then reverts to the
previously selected patch.

Tuner mode

The 507 is initially set so that the auto-chromatic tuning function for the guitar activates
automatically when the Bypass mode is invoked. In Bypass mode, pick an open string to be
tuned. The closest note will be shown on the display.

When the tuning function is active, the parameter cursor
LEDs serve as tuning meter, designed to enhance tuning
precision during fine adjustments.

Turning tuning function off

If you do not want to activate the tuning function in Bypass
mode, press the STORE and EDIT keys simultaneously for
more than one second in Play mode. The tuning function will be turned off, and this setting will
be stored even when the power is turned off. When you turn the function off, the display will
show "tunEr oFF" (tuning function off).

To turn the tuning function on, press the same keys simultaneously again. The display will show
"tunEr on" (tuning function on).

NOTE:  Please note that the tuning function may not operate properly if other effect modules between the

guitar and the 507 are on.

Selecting Patches

Using the Bypass/Tuner Mode

PATCH

DOWN

PATCH

UP

Patch switching 

24 patches are available 

Bank switching  

 Banks A, b, C, d, E, F are available  

BANK UP

BANK DOWN

BANK F

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK E

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK d

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK C

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK b

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK A

PATCH 1

PATCH 2

PATCH 3

PATCH 4

Pitch is too high

Correctly tuned

Pitch is too low

7

8

Press

Release immediately

Tuning function (only when the tuning function is ON)

Currently selected 

patch is displayed

Do = C

Do# = C#

Re = D

Regular tuning

6th string
1st string

 4th string

Mi = E

Fa = F

Fa# = F#

Regular tuning

Regular tuning

3rd string

Regular tuning

5th string

Regular tuning

2nd string

Re# = D#

So = G

So# = G#

La = A

La# = A#

Si = B

Input signal 

standby condition

&

w

& # w

&

w

& # w

&

w

&

w

& # w

&

w

& # w

&

w

& # w

&

w

Bank/patch switching

when Bank Hold is off

(initial setting)

Bypass ON/OFF  

The bypass function is invoked by pressing the left and right 
patch pedals simultaneously.
To cancel the Bypass/Tuner mode, just press one of the 
patch pedals.

Calibration 

Select reference pitch for auto-chromatic 
guitar tuner (calibration). 

Press both 
pedals together

* The reference pitch (A) can be adjusted in the range
  from 435 to 445 Hz. When the BANK key is pressed 
  in Bypass/Tuner mode, this is shown as "35" to "45" 
  on the display for a second. Adjust to the suitable 
  value. At power-on, the setting is 440 Hz (40).

Tuner ON/OFF 

Pressing the EDIT key and the STORE key simultaneously for more than one second in 
Play mode will allow you to select whether or not to activate the tuning function in Bypass 
mode. When you change the setting, the display will show"tunEr oFF" (tuning function off) 
or "tunEr on" (tuning function on) according to the setting. 

Содержание 507 REVERB

Страница 1: ...ttery to make sure you choose the correct type If the 507 is not to be used for an extended period of time remove the battery from the unit If battery leakage has occurred wipe the battery compartment and the battery terminals carefully to remove all remnants of battery fluid While using the unit the battery compartment cover should be closed Avoid using your 507 in environments where it will be e...

Страница 2: ...ff When you turn the function off the display will show tunEr oFF tuning function off To turn the tuning function on press the same keys simultaneously again The display will show tunEr on tuning function on NOTE Please note that the tuning function may not operate properly if other effect modules between the guitar and the 507 are on Selecting Patches Using the Bypass Tuner Mode PATCH DOWN PATCH ...

Страница 3: ...ck When the optional FP01 expression pedal and FS01 foot switch are connected to this jack it can serve as the external control jack When the optional expression pedal FP01 is connected it can serve for controlling the mix level of the effect When the optional foot switch FS01 is connected chorus can be switched on or off externally DISPLAY Displays information required to operate the 507 Play mod...

Страница 4: ...n selected Range of setting 0 50 Range of setting 0 50 Larger values result in a more pronounced high range reverb for a bright tone The value changes in increments or decrements of 1 each time the or key is pressed When the keys are pressed simultaneously the value changes in tens 10 20 50 Larger values result in more frequent repetitions The value changes in increments or decrements of 1 each ti...

Страница 5: ...5 When wishing to recall only a particular patch select the patch number in step 3 using the same procedure as for normal patch selection 6 When the desired patch has been selected press the STORE key The flashing rate increases and the contents of the selected patch are recalled 7 Recalling of individual patches can be carried out continuously When you wish to terminate the process press the EDIT...

Страница 6: ...ad is off pressing the patch UP pedal will change the number on the display the number flashes but until the user confirms the choice the sound remains that of patch 1 To turn Direct Load on or off keep the STORE key depressed for at least 1 second To confirm a choice after selecting a patch with Direct Load off press both patch pedals simultaneously Patch Switching Application Bank Hold ON Patch ...

Отзывы: