background image

The 24 patches can be selected easily by
pressing the patch pedals. The right patch
pedal switches to the next patch and the
left patch pedal switches to the previous
patch. 
In the initial condition, the 505 is set up
so that the patch pedals select patches
continuously, but you can also set up the
unit so that patches are switched only
within a certain bank [see the section
"Patch Switching (Application: Bank
Hold")]. 
Bank switching is performed with the
VALUE + / - keys. 

If for example the currently selected patch
is patch 2 of bank A, and you want to
switch to patch 3 of bank C, you would
need to press the UP pedal nine times.
Instead, you can press the VALUE + key
twice and then the UP pedal once. 

If the optional FS01 is connected to the
CONTROL IN jack on the rear panel, the
foot switch can be used as a bank UP
pedal. This allows full foot control, which
is highly convenient during a
performance. 

In the Bypass mode, the effects of
the 505 are temporarily turned off,
so that the original sound of the
instrument only is heard. In this
mode, the auto-chromatic tuning
function is also active. It is also
possible to activate muting, to
prevent the tuning sound from
being sent to the output. 

Bypass and mute condition 

Pressing both patch pedals simultaneously activates the Bypass or Mute mode. 

• For bypass mode: Press and immediately release the patch pedals. 

• For mute mode: Press patch pedals for at least 1 second. 

To cancel the bypass or mute condition, simply press one of the patch pedals. The unit then
reverts to the previously selected patch. 

Tuning function 

When the 505 is in the Bypass or Mute mode, the tuning function is activated automatically. Pick
an open string to be tuned. The closest note is shown on the display. 

When the tuning function is active, the
parameter cursor LEDs serve as tuning
meter, designed to enhance tuning
precision when making fine adjustments. 

Selecting Patches 

Using the Bypass (Mute)/Tuner Mode

PATCH

DOWN

PATCH

UP

Patch switching 

24 patches are available 

Bank switching  

 Banks A, b, C, d, E, F are available  

BANK UP

BANK DOWN

BANK F

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK E

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK d

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK C

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK b

PATCH 1

PATCH 2

PATCH 3

PATCH 4

BANK A

PATCH 1

PATCH 2

PATCH 3

PATCH 4

Bypass (Mute)/Tuner mode ON  

Pressing both patch pedals simultaneously turns
the Bypass (Mute)/Tuner mode on. To turn the 
mode off, simply press one of the two patch pedals.  

Calibration 

Select reference pitch for auto-chromatic
 guitar tuner (calibration)  

Press both 
pedals together

* Reference pitch (A) can be adjusted in
the range from 435 to 445 Hz. This is
shown as "35" to "45" on the display.
The normal setting is 440 Hz (40).

Pitch is too high      Correctly tuned        Pitch is too low 

7

8

Press                          Release immediately      Tuner mode 

Currently selected

patch is indicated

Currently selected

patch is indicated

Press for 1 s or more                                      Release        Mute mode

Do = C

Do# = C#

Re = D

Re# = D#

Input signal 

standby condition

Regular tuning

Regular tuning

6th string
1st string

3rd string

 4th string

Mi = E

Fa = F

Fa# = F#

So = G

So# = G#

La = A

La# = A#

Si = B

Regular tuning

Regular tuning

5th string

2nd string

Regular tuning

Bank/patch switching

when Bank Hold is off 

Содержание 505 guitar

Страница 1: ...ry from the unit If battery leakage has occurred wipe the battery compartment and the battery terminals carefully to remove all remnants of battery fluid While using the unit the battery compartment cover should be closed Avoid using your 505 in environments where it will be exposed to Extreme temperature High humidity or moisture Excessive dust or sand Excessive vibration or shock The 505 is a pr...

Страница 2: ...es Direct Load function When the key is held down for at least 1 second in the Play mode the Direct Load function is turned on or off EDIT key This key serves to toggle between the Play mode where effects are used for playing the instrument and Edit mode where the user can freely change patch settings The Edit mode is also used to select effect parameters When the key is pressed while a Delay Reve...

Страница 3: ... then reverts to the previously selected patch Tuning function When the 505 is in the Bypass or Mute mode the tuning function is activated automatically Pick an open string to be tuned The closest note is shown on the display When the tuning function is active the parameter cursor LEDs serve as tuning meter designed to enhance tuning precision when making fine adjustments Selecting Patches Using t...

Страница 4: ...ard when the patch UP pedal is pressed three times When Direct Load is off pressing the patch UP pedal will change the number on the display the number flashes but until the user confirms the choice the sound remains that of patch 1 To turn Direct Load on or off keep the STORE key depressed for at least 1 second To confirm a choice after selecting a patch with Direct Load off press both patch peda...

Страница 5: ... mode in which patches can be edited is called the Edit mode To switch from normal Play mode to Edit mode briefly press the EDIT key Do not keep the EDIT key depressed because if the key is held for 1 second the Bank Hold mode will be activated Immediately after switching from the Play mode to the Edit mode the parameter cursor flashes at the highest position COMP module regardless of which patch ...

Страница 6: ... number in step 3 using the same procedure as for normal patch selection 6 When the desired patch has been selected press the STORE key The flashing rate increases and the contents of the selected patch are recalled 7 Recalling of individual patches can be carried out continuously When you wish to terminate the process press the EDIT key The unit then returns to the Play mode Turning the unit off ...

Отзывы: