FEATURES:

• Controls up to 600 watts of heating or cooling devices (600 W 

maximum resistive load).

• Remote Temperature Sensor with 6 foot (185 cm) cable.
• Controls temperature by turning on heating devices in “HEAT” 

mode or by turning on cooling devices (e.g., fan) in “COOL” mode.

PROGRAMMING THE CONTROL UNIT:

Upon plugging in your new 

REPTITEMP® Digital Thermostat

 for the first time, the digital display will illuminate and show all of the symbols 

for a brief moment before showing the default factory settings. After programming the control unit, the new settings will be stored in the 
controller’s memory. In the event of a power failure, or if the unit becomes unplugged, the programmed settings will resume once power is 
restored. Wait until after the unit has been programmed before plugging in heating or cooling devices.

A. PROGRAMMING the TEMPERATURE SETTING:

The 

REPTITEMP® Digital Thermostat

 will turn heaters or cooling devices on and off to maintain the optimum temperature in your 

terrarium. The temperature can be set in either Fahrenheit (°F) or Celsius (°C) mode. Perform the following steps to program the temperature 
setting of your controller: 

1.

 Press and release the 

MODE

 button to select the temperature scale (°C or °F). 

2.

 To adjust the temperature setting, press the “Set” button and the temperature above the word 

PROGRAM

 will flash. While the 

numbers are flashing, press the 

SET

 button once to change the programmed temperature one degree. Press and hold the button to 

increase by several degrees. If you pass the desired setting, press and hold the 

SET

 button to cycle through the numbers again. The 

controller will automatically exit programming and return to the normal display 5 seconds after the desired temperature is set, and 
the programmed temperature will appear above the word 

PROGRAM.

 

3.

 The temperature program is now set and can be changed at any time by pressing the 

SET

 button.

B. SELECTING HEAT or COOL MODE:

In 

HEAT

 mode, the controller will turn on heating devices (e.g., heat lamps, under tank heaters, ceramic heat emitters) when the actual 

temperature in your terrarium drops below the programmed temperature setting. In 

COOL

 mode, the controller will turn on a cooling device 

(e.g., fan) when the temperature in your terrarium rises above the programmed temperature setting. To switch between 

HEAT

 and 

COOL

 

mode, press and hold the 

MODE

 button until 

HEAT

 or 

COOL

 flashes on the display, then press the 

SET

 button to switch between modes. 

When the desired mode is selected, wait 5 seconds for the controller to automatically exit programming and save the setting.

• LCD display with convenient two-button programming.
• Temperature control range: 50°F to 122°F (10C to 50C).
• Built in memory stores settings in case of power failure.
• Alarm flashes & sounds when temperature reaches extreme high 

or low levels.

SAFETY INSTRUCTIONS:

IMPORTANT:

 In order to reduce the risk of fires, electric shock, or 

personal injury, read and save these instructions prior to operation.

• Use only with a 120 V, 60 Hz. grounded outlet.
• 

WARNING

 – 

DO NOT

 use this device to control heaters exceeding 600 

watts (maximum resistive load). 

DO NOT

 use this device to control 

cooling appliances like fans or compressors exceeding 150 watts 
(maximum inductive load).

• This unit has no serviceable parts. 

DO NOT

 open the housing for any 

reason as doing so will void the warranty. Contact Zoo Med to arrange 
for repair or replacement during the warranty period.

• 

DO NOT

 stretch or strain wires or power cords connected to this device.

• 

DO NOT

 immerse any of the thermostat components in water. Keep the 

Programmable Control Unit outside of cages and terrariums; only the 
remote sensor is to be inside the cage/terrarium.

• 

DO NOT

 allow heavy objects to rest on any of the 

thermostat components or associated cables and 
power cords.

• This thermostat is 

NOT

 designed to control the 

temperature of a rock heater (use Zoo Med’s 
ReptiTemp Rheostat instead).

• 

DO NOT

 operate the unit with a damaged cord, plug, 

or other component.

• 

DO NOT

 use an adapter that converts the grounded 

three-prong plug to a two-prong plug.

• 

DO NOT

 alter or modify this product. Contact 

an electrician if you are unsure about the 
electrical connection.

• 

FOR INDOOR USE ONLY. NOT FOR USE OUTSIDE.

78

73

SET

MODE

ACTUAL

PROGRAM

REPTITEMP DIGITAL

THERMOSTAT

REPTITEMP DIGITAL

THERMOSTAT

77

85

SET

MODE

ACTUAL

PROGRAM

REPTITEMP DIGITAL

THERMOSTAT

REPTITEMP DIGITAL

THERMOSTAT

ALARM

77

87

SET

MODE

ACTUAL

PROGRAM

REPTITEMP DIGITAL

THERMOSTAT

REPTITEMP DIGITAL

THERMOSTAT

HEAT MODE OPERATION:

When heat mode is selected, the word 

HEAT

 shows on the display at all times. When the temperature drops below the programmed setting, 

the heating device is turned on and the flame icon appears next to the word 

HEAT

. When the terrarium reaches the set temperature, the 

heater is turned off and the flame icon disappears. The word 

HEAT

 remains on to show that the controller is set to heat mode.

COOL MODE OPERATION:

When cool mode is selected, the word 

COOL

 shows on the display at all times. When the temperature rises above the programmed setting, 

the cooling device is turned on and the snowflake icon appears next to the word 

COOL

. When the terrarium reaches the set temperature, the 

cooling device is turned off and the snowflake icon disappears. The word 

COOL

 remains on to show that the controller is set to cool mode.

C. PROGRAMMING the ALARM:

The alarm feature is turned off in the default settings but can easily be enabled, and the alarm will alert you when the temperature in the 
terrarium is above or below the programmed settings. When the alarm is triggered, the controller will beep and the word 

“ALARM”

 will flash 

on the display along with the bell icon (see figure 3). Press the 

SET

 button to silence the alarm. 

Enter the programming function by pressing and holding the 

MODE

 button until 

“HEAT”

 or 

“COOL”

 flashes on the display, then press and 

release the 

MODE

 button once more until 

“ALARM”

 flashes on the display, along with the numbers above the word 

“ACTUAL.”

 While still 

flashing, press the 

SET

 button to program the temperature change that will trigger the alarm. When the temperature rises above or falls 

below the programmed temperature by the set number of degrees, the alarm will activate. (i.e., if the temperature setting of the thermostat is 
85°F, and the Temperature Alarm Setting is 10, the alarm will be activated if the temperature rises above 95°F or falls below 75°F). When 
the alarm is set to 00 it is disabled. After programming the alarm, wait 5 seconds for the controller to exit programming and save the 
settings. Even though the alarm is set, the word 

ALARM

 will disappear from the display when the controller exits programming and resumes 

normal function.

Figure 2

Figure 3

Figure 1

Содержание RT-600

Страница 1: ...g in the thermostat Your REPTITEMP Digital Thermostat unit should already be plugged in and programmed If you have unplugged the REPTITEMP Digital Thermostat to move it plug it back in now The programmed settings are stored in the memory and will not need to be reset 5 Plug in Heating Cooling Device Finally plug in the heating or cooling device to the socket on the front of the controller Check to...

Страница 2: ... parts DO NOT open the housing for any reason as doing so will void the warranty Contact Zoo Med to arrange for repair or replacement during the warranty period DO NOT stretch or strain wires or power cords connected to this device DO NOT immerse any of the thermostat components in water Keep the Programmable Control Unit outside of cages and terrariums only the remote sensor is to be inside the c...

Страница 3: ... parts DO NOT open the housing for any reason as doing so will void the warranty Contact Zoo Med to arrange for repair or replacement during the warranty period DO NOT stretch or strain wires or power cords connected to this device DO NOT immerse any of the thermostat components in water Keep the Programmable Control Unit outside of cages and terrariums only the remote sensor is to be inside the c...

Страница 4: ...g in the thermostat Your REPTITEMP Digital Thermostat unit should already be plugged in and programmed If you have unplugged the REPTITEMP Digital Thermostat to move it plug it back in now The programmed settings are stored in the memory and will not need to be reset 5 Plug in Heating Cooling Device Finally plug in the heating or cooling device to the socket on the front of the controller Check to...

Отзывы: