MEYERTECH DIVISION
ISSUE 05
Page 5
3.
INSTALLATION
To obtain the optimum performance from your ZVR-510 please take time to read this manual before
commencing installation. If you have any questions or problems our staff will be pleased to assist you
on the technical helplines listed on page 27.
WARNING
THIS EQUIPMENT CONTAINS HAZARDOUS VOLTAGES. THIS
EQUIPMENT MUST BE EARTHED TO PREVENT FIRE OR SHOCK
HAZARD. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR
MOISTURE.
Unpack the ZVR-510 and check the contents against the list below.
♦
ZVR-510 PCB
♦
Transformer 20V 100VA
3.1 LINK SETTINGS
Links N.O. and N.C. are used to select Alarm contact types.
NEVER
connect both N.O. and N.C.
N.C.
Fit for Normally Closed Contacts.
N.O.
Fit for Normally Open Contacts.
LD
Fit for ZVR-510
LENS
Selects 6 or 12V camera drive level.
422/485
Sets up serial port. (Link out - 422 ; Link in - 485)
422 ( x2 )
Fit for receiving via RS422 and transmitting via VICTA COAX.
Unfitted receives and transmits via VICTA COAX
Note : For Link locations see Appendix A on page 23.
VC1
Variable trimmer capacitor adjusts caption widths of OSD text.
3.2 CONNECTING THE ZVR-510
Connect up the ZVR-510 in accordance with the accompanying wiring diagram, paying special
attention to the maximum ratings and the notes below.
1. The ZVR-510 MUST be Earthed at the AC input supply terminal.
2. NEVER run cables directly under the PCB as this may interfere with the operation of the
Telemetry ZVR-510 and other camera head equipment.
3. ALWAYS use Screened cables for low voltage and signal cables ensuring the screen is
connected to 0V or Earth.