Operating
13
Waste collection day number
Daily and total value of the counter is increased if in day
at least 10 press cycles was performed
Vehicle stopped for wastes
collection
Daily and total value of the counter is increased every
time the vehicle is stopped and there is demand for
hydraulic pressure
Engine running time
The value of the counter is increased when engine
speed is greater than zero. In case of lack of information
about vehicle speed, system detects engine state every
time the ignition is on
Waste collection time
Daily and total value of the counter is increased when
the vehicle is ready to work. Vehicle is ready to collect
waste when pump is on
–
start button on Command
Module is on
Running time vehicle at neutral
position
Daily and total value of the counter is increased when
the vehicle is stopped (N on the screen) and ready to
work
Compaction running time
Daily and total value of the counter is increased when
press oil demand is greater than zero
Lifter running time
Daily and total value of the counter is increased when
lifter oil demand is greater than zero
Hydraulic running time
Daily and total value of the counter is increased when
the vehicle is stopped (N on the screen) and pump is on
(Start button on Command Module)
3.5
E
MPTYING
Emptying menu allows to control the tailgate and the pushing wall from the terminal. Holding
button
opens the tailgate. Button
closes it and it is active only when the tailgate is
opened. Tailgate cannot be closed fully from the terminal it has to be closed completely with
the buttons on the side of the body. Button
retracts the pushing wall and button
ejects it - it is active only when the tailgate is closed.