background image

2

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

*AGRICULTURAL/FOOD PROCESSING AND PERMANENT INDUSTRIAL 

INSTALLATIONS CONTAINING LIMITED QUANTITIES (5% BY VOLUME) OF 

WASTE OR ABRASIVES AND PERMANENT INDUSTRIAL INSTALLATIONS

15 Months After Shipment - Limited Warranty

MONTHS                0-9             9-15

Rotor & Stator      0%              50%

Shaft Seals         25%              50%

Impeller                   25%              50%

Ball Bearings         0%              50%

Pump Housing        25%              50%

Controls and accessories included for nine months.

*CONSTRUCTION - OTHER PORTABLE INSTALLATIONS

Nine Months After Shipment - Limited Warranty

MONTHS                  0-9

Rotor & Stator           0%

Shaft Seals           25%

Impeller                    25% 

Ball Bearings             0%

Pump Housing        25%

Controls and accessories included for nine months.

Limited Repair Warranty at an Authorized Service Station.

Beginning on the date of repair, the term of the repair warranty shall be the longer of 

the unexpired original warranty term or 30 days.

Limited Replacement Parts Warranty - 30 Days After Purchased.

Each Zoeller X61 HD Series Pump installation is required to have a completed Zoeller Engineered Products Start-up Report (ZM1074). The report is to be completed by 

an approved Start-up Technician in the presence of the installing contractor. A copy of this report will be kept on file at the Zoeller Engineered Products offices in Louisville, 

KY.  

Failure to comply with the requirement will void the 5 year pro-rated warranty agreement.

Limited Warranty 

Zoeller Engineered Products’ sole obligation under all the above warranties shall be 

to make repairs and to replace parts when necessary on products that have been 

returned to Zoeller Engineered Products or an authorized service facility and found to 

be defective by the company.  Part(s) that fail and that inspection determines to be 

defective in material or workmanship, will be repaired, replaced, or remanufactured 

at Zoeller Engineered Product’s option provided, however, that by so doing we shall 

not be obligated to replace an entire assembly, the entire mechanism, or the complete 

unit.  Major components and controls not manufactured by the company are covered 

by the original manufacturer warranty in lieu of this warranty.  This warranty shall not 

apply to any product or part of a product, including pumps, controls, lifting devices, 

basins, and power cables which are damaged or subject to misuse, accident, neglect, 

operated outside the limits of the pump curves, used in a manner contrary to the printed 

instruction, or damaged due to a defective power supply, improper electrical protection, 

or faulty installation or repair.

The company will not be responsible for travel expenses, rented equipment, outside 

contractor fees, or unauthorized repair shop expenses.  No allowance will be made 

for shipping charges, damages, labor or other charges that may occur due to product 

failure, repair, or replacement.

This warranty does not apply to any material that has been disassembled without prior 

approval of Zoeller Engineered Products, subjected to misuse, misapplication, neglect, 

alternation, accident or act of God; that has not been installed in accordance with Zoeller 

Engineered Products installation instructions; that has been exposed to but not limited to 

hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.) or other abrasive or 

corrosive substances, is in lieu of all other warranties expressed or implied.

Contact authorized service station to obtain any needed repair replacement parts.  For 

additional information pertaining to our warranty or if service cannot be obtained locally, 

contact Zoeller Engineered Products, 3649 Cane Run Road, Louisville, Kentucky 40211-

1961,  Attn:  Customer Service.

ZOELLER ENGINEERED PRODUCTS EXPRESSLY DISCLAIMS LIABILITY FOR 

SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES OR BREACH OR 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF 

FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE 

LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitation on the duration of an implied warranty, so the above 

limitation may not apply to you.  Some states do not allow the exclusion or limitation 

of incidental or consequential damages, so the above limitation or exclusion may not 

apply to you.

This warranty gives you specific legal rights, and you may also have other rights which 

vary from state to state.

Zoeller Engineered Products neither assumes nor authorizes any person or company 

to assume for it any other obligation in connection with the sale of its equipment.  Any 

enlargement or modification of this warranty by any other party is their sole responsibility.  

No other warranties expressed or implied, including implied warranties of merchantability 

and fitness for a particular purpose will apply.

Limitations

The Zoeller Engineered Products warrants its X61 HD Series of submersible pumps 

to the original owner to be free from defects in workmanship and materials under 

the following conditions and limitations. The owner pays the applicable percentage 

of the list price of the following parts in effect at time of replacement in the specified 

installations*.  

Conditions

1. Approval of installation and start up of the equipment by the Zoeller Authorized 

Factory Representative.

2.  Removal, reinstallation and transportation charges shall be borne by the buyer.

3.  Labor charges for warranty repair shall not be assumed by the company for repairs 

made after one year from date of installation. Returns must have prior authorization 

from the company.

4.  Hazardous Environment Series pumps have special repair procedures. Reference 

Policy #ZM1462-3c or contact the Zoeller Product Support Department. 

5.  Controls and accessories warranty (See specific warranty below).

*MUNICIPAL SEWAGE PERMANENT INSTALLATION

Five Year (10,000 hr) Months After Shipment - Limited Warranty

MONTHS             0-18            19-30            30-45            46-60

HOURS              0-3,000      3,000-5,000     5,000-7,500     7,500-10,000

Rotor & Stator      0%              30%              50%               80%

Shaft Seals    

0%              30%              50%               75%

Impeller          

0%              30%              50%               80%

Ball Bearings       0%              50%              80%              100%

Pump Housing       0%              30%              50%              100%

Controls and accessories included for 18 months.

Содержание X61 HD Series

Страница 1: ...1074 for a proper start up and warranty protection Many items contained within when followed correctly will not only ensure a long and problem free life for the pump but also save time and money during installation Should further assistance be necessary please call our Product Service Department at 1 800 928 PUMP 7867 Safety Instructions CAUTION TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MA JOR ...

Страница 2: ...r Engineered Products subjected to misuse misapplication neglect alternation accident or act of God that has not been installed in accordance with Zoeller Engineered Products installation instructions that has been exposed to but not limited to hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances is in lieu of all other warranties expressed or im...

Страница 3: ...handling various sizes of solid waste be of the bottom intake design to reduce clogging and seal failures If a check valve is incorporated in the installation a vent hole approx 3 16 must be drilled in the discharge pipe below the check valve and pit cover to purge the unit of trapped air Water stream will be visible from this hole during pump run periods This vent hole should be checkedperiodical...

Страница 4: ...ll be visible from this hole during pump run periods Also a vent hole is drilled in the pump housing Be sure that this hole is cleared during any servicing 7 Vent gases and odors to the atmosphere through vent pipe per Local and State codes 8 Secure power cord to avoid entanglement with variable level float switch mechanism 9 Do not reduce pump discharge pipe below 3 IPS size 10 Basin must be in a...

Страница 5: ...t will activate whenever water is present in the cavity Whenever the seal leak light is activated indicating that the lower seal has failed the pump should be removed and serviced in order to avoid damage to the motor 3 The green wire shall be connected to a ground lug in the panel CONTROL PANELS These pumps require a control panel The control panel rarely requires an explosion proof rating since ...

Страница 6: ...panel For components purchased separately used the diagram for installation and hookup Single phase models are nonautomatic To operate automatically a control panel must be added to the power circuit Follow the instructions provided with the panel ZEPA0478 WIRING DIAGRAM WIRING DIAGRAM ZEPA0538 MODELS X6120 X6121 USING SUPCO PR90 RELAY BEFORE 10 1 07 MODELS X6111 X6122 X6123 X6124 AND X6120 X6121 ...

Страница 7: ...harge valves should be placed in the fully open position Sys tems should not be operated for extended periods of time with the discharge valves partially closed due to damaging the valve SHUTDOWN PROCEDURES Ifasystemisshutdownformorethansixmonths thefollowingisrecommended Pumps If pit is to remain dry then the pump can remain in the pit With the pump in the pit it should be operated for five minut...

Страница 8: ...ips overload or blows fuse COMMON CAUSES Incorrect Voltage Unbalanced power source Incorrect motor rotation Negative or low head Excessive water temperature Impeller or seal mechanically bound Defective capacitor or relay Motor shorted Lost one line in a Three Phase unit C Pumps starts and stops too often Check valve stuck open Level controls out of adjustment Temperature sensor tripping Thermal o...