background image

SECTION: Z3.30.190

ZM2210

Rev. A

0515

Supersedes

0214

NOTICE TO INSTALLER:  Instructions must remain with installation.

OWNER’S MANUAL

X61 HD HAZARDOUS ENVIRONMENT  CLASS 

I

,

DIVISION 1, GROUP C & D SERIES SUBMERSIBLE

 UNITS

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

 

Congratulations on the purchase of the Zoeller X61 HD Series 

submersible pump. 

This pump has been constructed in compliance 

with FM and CSA testing. These requirements enable the unit to 

be listed as an explosion proof pump rated for use in Class 

I

Division 1, Group C & D environments.

 Zoeller pumps are designed 

for pumping sanitary sewage from submersible lift stations. Since 

1939 the name Zoeller has represented the standard for submersible 

dewatering and sewage pumps. The same high quality workmanship 

and easy maintenance design has been incorporated into this line of 

heavy-duty solids-handling submersible sewage pumps. This Zoeller 

Rev. 10/10

Model Number:

 _______________

 Date Code:

  _______________

Serial Number:  Pump 1_____________  Pump 2_____________ 

 Simplex 

  Panel P/N ______________________________

 Duplex 

  Rail System P/N ________________________

Job Name: ____________________________________________
Distributor:

 ____________________________________________

Sales Order Number:

 ____________________________________

Contractor:

 ____________________________________________

Date of Installation:

 _____________________________________

System Readings During Operation: Voltage

 _____

 Amps 

_____

 

pump will provide years of trouble-free service when installed according 

to the manufacturers’ recommendations.

 

This manual incorporates the installation, operation, maintenance, 

and service instructions into one document to aid in the ownership of a 

Zoeller submersible solids handling product. Please read and review this 

manual before installing the product. Follow the steps and procedures 

listed on ZM1074 for a proper start-up and warranty protection. Many 

items contained within, when followed correctly, will not only ensure a 

long and problem-free life for the pump, but also save time and money 

during installation.  Should further assistance be necessary please call 

our Product Service Department at 1-800-928-PUMP (7867).

Safety Instructions

CAUTION

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MA-

JOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY  

INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.

THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION 

AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH 

THE PUMP.

This is a 

SAFETY ALERT SYMBOL.

When you see this symbol on the pump or in the 

manual, look for one of the following signal words 

and be alert to the potential for personal injury or 

property damage.

Warns of hazards that 

WILL

 cause serious personal    

injury, death or major property damage.

Warns of hazards that 

CAN 

cause serious personal 

injury, death or major property damage.

Warns of hazards that 

CAN 

cause personal injury 

or property damage.

INDICATES SPECIAL INSTRUCTIONS WHICH ARE 

VERY IMPORTANT AND MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS 

PRIOR TO PERFORMING ANY WORK ON THIS PUMP.

MAINTAIN ALL SAFETY DECALS.

REFER TO WARRANTY ON PAGE 2.

Owner’s Information

Table of Contents

Safety Instructions .......................................................................1
Limited Warranty ..........................................................................2
Preinstallation Information ..........................................................3
Electrical Data ...............................................................................3
Typical Dewatering Installation ...................................................4
Typical Sewage Installation  ........................................................4
Pump Wiring Instructions .........................................................5-6
Operation .......................................................................................7
Maintenance ..................................................................................7
Service Checklist ..........................................................................8

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

Register your 

Zoeller Engineered Product 

on our website:

http://reg.zoellerengprod.com/

R

Certified to CSA Standard

C22.2 No. 145

Standard 3600 & 3615

Standard 3600 

& 3615

Содержание X61 HD Series

Страница 1: ...1074 for a proper start up and warranty protection Many items contained within when followed correctly will not only ensure a long and problem free life for the pump but also save time and money during installation Should further assistance be necessary please call our Product Service Department at 1 800 928 PUMP 7867 Safety Instructions CAUTION TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MA JOR ...

Страница 2: ...r Engineered Products subjected to misuse misapplication neglect alternation accident or act of God that has not been installed in accordance with Zoeller Engineered Products installation instructions that has been exposed to but not limited to hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances is in lieu of all other warranties expressed or im...

Страница 3: ...handling various sizes of solid waste be of the bottom intake design to reduce clogging and seal failures If a check valve is incorporated in the installation a vent hole approx 3 16 must be drilled in the discharge pipe below the check valve and pit cover to purge the unit of trapped air Water stream will be visible from this hole during pump run periods This vent hole should be checkedperiodical...

Страница 4: ...ll be visible from this hole during pump run periods Also a vent hole is drilled in the pump housing Be sure that this hole is cleared during any servicing 7 Vent gases and odors to the atmosphere through vent pipe per Local and State codes 8 Secure power cord to avoid entanglement with variable level float switch mechanism 9 Do not reduce pump discharge pipe below 3 IPS size 10 Basin must be in a...

Страница 5: ...t will activate whenever water is present in the cavity Whenever the seal leak light is activated indicating that the lower seal has failed the pump should be removed and serviced in order to avoid damage to the motor 3 The green wire shall be connected to a ground lug in the panel CONTROL PANELS These pumps require a control panel The control panel rarely requires an explosion proof rating since ...

Страница 6: ...panel For components purchased separately used the diagram for installation and hookup Single phase models are nonautomatic To operate automatically a control panel must be added to the power circuit Follow the instructions provided with the panel ZEPA0478 WIRING DIAGRAM WIRING DIAGRAM ZEPA0538 MODELS X6120 X6121 USING SUPCO PR90 RELAY BEFORE 10 1 07 MODELS X6111 X6122 X6123 X6124 AND X6120 X6121 ...

Страница 7: ...harge valves should be placed in the fully open position Sys tems should not be operated for extended periods of time with the discharge valves partially closed due to damaging the valve SHUTDOWN PROCEDURES Ifasystemisshutdownformorethansixmonths thefollowingisrecommended Pumps If pit is to remain dry then the pump can remain in the pit With the pump in the pit it should be operated for five minut...

Страница 8: ...ips overload or blows fuse COMMON CAUSES Incorrect Voltage Unbalanced power source Incorrect motor rotation Negative or low head Excessive water temperature Impeller or seal mechanically bound Defective capacitor or relay Motor shorted Lost one line in a Three Phase unit C Pumps starts and stops too often Check valve stuck open Level controls out of adjustment Temperature sensor tripping Thermal o...

Отзывы: