P/N 012224
1. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) and in accordance
with national electrical code and local codes.
2. Make certain that the receptacle is within the reach of the pump’s
power supply cord. DO NOT USE AN EXTENSION CORD.
Extension cords that are too long or too light do not deliver
sufficient voltage to the pump motor. But more important, they
could present a safety hazard if the insulation were to become
damaged or the connection end were to fall into the sump.
3. Testing for Ground. As a safety measure, each electrical outlet
should be checked for ground using an Underwriters Laboratory
Listed circuit analyzer which will indicate if the power, neutral
and ground wires are correctly connected to your outlet. If they
are not, call a qualified electrician.
4. For electrical safety, it is recommended that a GFCI be in-
stalled.
5.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
Single
phase pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock.
DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND
PIN
. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) in accordance with
national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
7. Risk of electric shock - These pumps have not been investigated
for use in swimming pool and marine areas.
8. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
Notice to iNstaller: instructions must remain with installation.
sectioN: 6.10.060
FM1648
1109
Supersedes
0107
MODELS 108 and 138
CRAWL SPACE PUMPING SYSTEM
PREINSTALLATION CHECKLIST
®
Zoeller Pump Company is one of the oldest and largest pump manufacturers in the U.S. and has a history of supplying innovative
products and services to its customers.
Through research and development, design, testing and manufacturing, we have been able to bring products to the market that solve
problems that plague consumers, industry, and the environment. This commitment to our customers has enabled them to enjoy returns
of our joint efforts.
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
DO NOT
remove the test plugs in the cover nor the motor housing.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should
be retained for future reference.
1. Check to be sure your power source is adequate for handling
the voltage requirements of the motor, as indicated on the pump
or basin plate.
2. Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity. A separate branch
circuit is recommended, sized according to the National Electri-
cal Code for the current shown on the pump name plate.
3.
Pump should be checked frequently for debris and/or build up
which may interfere with the float “on” or “off” position. Repair
and service should be performed by a Zoeller Pump Company
Authorized Service Station only.
4. A CHECK VALVE MAY BE REQUIRED TO REDUCE UNNEC-
ESSARY CYCLING OF PUMP.
5. Dewatering pumps are not designed or intended for handling
raw sewage.
6. Maximum operating temperature for Crawl Space Drain Pumps
must not exceed 130°F (54°C).
SEE BELOW FOR LIST OF WARNINGS
SEE BELOW FOR LIST OF CAUTIONS
refer to warraNty page 2.
NOTE:
Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certified pumps are
certified to CSA Standard C22.2 No. 108.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.