background image

3

The DC controller is equipped with a 10 amp charger for main tain ing the battery in a ready state and re charg ing the battery after use when 

AC power is restored. Time for recharge depends upon the amount of power consumed by the pumping cycle during the AC power inter-

 rup tion. The pump may go back to the ready run position in a very short period of time. A com pletely drained battery may require up to 24 

hours for full recharge. If after 24 hours of charging the battery has not reached 6 volts, the alarm will sound and not reset until the battery 

is brought up to a voltage of 6.5-7.0 volts.

© Copyright 2009 Zoeller Co. All rights reserved.

MODELS:

507-C

507-D

ITEM

DESCRIPTION

QTY

4/96

thru

10/05

11/05

thru

Current

DC backup pump

1

010475

017198

Plastic battery box with safety closure strap

1

005702

005702

DC control charger with terminals

1

011323

011323

4 “Off”/”On” 

fl oat switch

1

017197

017197

1½" x 5" long PVC pipe nipple

1

005639

N/A

6 Check 

valve

(2) REV C - (1) REV D

005636

005636

Reducer hose coupling and clamp

1

30-0188

N/A

1¼" x 1" PVC reducer fi tting

1

005642

N/A

1" pipe to hose adapter elbow

1

005643

N/A

10 

1" hose coupling and two clamps

1

005703

N/A

11 

1½" PVC pipe tee

1

005645

005645

12 

1½" 90 degree PVC pipe elbow

1

005644

N/A

13

1¼" x 1¼" PVC coupling

1

009129

N/A

14 

Pump mounting kit, includes brkt, S.S. worm drive clamp, two #10-24 screws 
and washers.

1

005704

N/A

15

Cable tie

1

005868

N/A

16

Anchors, wall

2

009691

009691

17

Bracket, control mounting

1

007779

007779

18

1½" x 1½" PVC coupling

1

N/A

009746

Checklist

Performance

The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. A deep-

cycle, 12 volt, 105 amp-hour marine battery or larger is rec om mended and will provide approximately 7½ hours of continuous pumping 

time in a sump pump installation with 8' of head pressure. In most installations the pump runs intermittently and the battery life is extended 

accordingly. Batteries with top terminals are recommended for ease of installation. These batteries contain acid and proper precaution must 

be taken when handling. Maximum battery size 12½" Length x 7" Width x 9½" Height.

Battery Selection

Discharge

Feet of Head

5

10

15

17.5

Flow

Gal. per min.

23

15

5

Shut-off

Head

The DC pump performance with fully charged 12V battery

The DC emergency pump is designed as a backup to your primary sump pump during unexpected power out ages or primary pump failure. 

The DC pump, elec tronic controls and all the parts required for in stal la tion are included except the battery which is supplied by the user. 

The system is de signed for installation in sumps with minimum of 18" di ame ter and 24" deep. For 18" x 22" applications, consult factory.

Description

Troubleshooting Information, 

continued

7.  Water level stays high. DC Pump continues to run.

  (a)  Battery is low.

  (b)  If power has been restored and water in sump re mains high 

check primary pump. Service if re quired.

   (c)  After several hours the battery will be restored to full charge.

8.  Alarm sounds during battery recharge cycle.

  (a)  Push alarm reset (max. 3 times). If condition persists, 

replace battery.

  (b)  To silence alarm if alarm will not reset, unplug the charger 

from 115V wall outlet, then disconnect the black lead from 

charger on negative (-) battery post. Check battery. Replace 

if necessary. Reconnect and refer to Installation (step 14).

Содержание Basement Sentry Series

Страница 1: ...or operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and is secured so the pump will turn on and off It is recommended that the pit be 18 in diameter or larger to accommodate both a primary and a DC backup pump SEE BELOW FOR LIST OF WARNINGS 1 Testing for Ground As a safety measure each electrical ...

Страница 2: ...Three year limited warranty valid only when a complete system is purchased and used as a backup to a primary dewatering system A complete system includes a Model 507 or 510 Basement Sentry and an Aquanot Battery 1 Inspect and test the system for proper operations at least every 3 months a Red power on indicator light should be on indicating AC power is on b Unplug primary pump and the control char...

Страница 3: ...ystem requires a good quality 12 volt battery to obtain maximum pumping time during a power outage A deep cycle 12 volt 105 amp hour marine battery or larger is recommended and will provide approximately 7 hours of continuous pumping time in a sump pump installation with 8 of head pressure In most installations the pump runs intermittently and the battery life is extended accordingly Batteries wit...

Страница 4: ...ent than the primary pump 4 If primary pump is installed disconnect power If the primary pump is a column pump with adjustable float and you are installing per figure 2 check the on point and adjust to approximately 7 from bottom of pump see figure 2 Mark the discharge pipe 7 above the on point of the primary column pump or 7 above the top of the primary submersible pump 5 If existing discharge pi...

Страница 5: ...o avoid airlocking DC PUMP PLUMBED IN LINE WITH SUBMERSIBLE PUMP OUTLET PUMP PRIMARY BATTERY BOX VERIFY WEEP HOLE IS PRESENT IN MAIN DISCHARGE LINE SEE PUMP INSTALLATION INSTRUCTIONS 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP BATTERY BOX OUTLET PRIMARY PUMP DC PUMP PLUMBED IN LINE WITH COLUMN PUMP 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN D...

Страница 6: ...D BY USER DC BACK UP PUMP CLAMP FLOAT SWITCH BLACK WITH RED TRACER TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE TO FLOAT RED LEAD 15 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH BLUE LEAD SPLICER WHITE OR PUMP ASSEMBLY 1 6 SUPPLIED BY CUSTOMER DISCHARGE PIPE TOP VIEW IMPORTANT MAKE SURE THIS LINE IS GLUED IN POINTING UP 11 18 ...

Страница 7: ...or over 7 hours and a Maintenance Free AGM Battery which will power the pump for over 3 hours These times are based on continuous pumping at 10 of static head Actual times will vary depending on static head volume of water entering the pit and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 minute reserve capacity or larger Do NOT use a maintena...

Страница 8: ...tery to the exterior Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector In no way are they meant to supersede the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer If the audible alarm associated with your CO detector is activated we recommend the following actions 1 Take imme...

Отзывы: