NOTICE TO INSTALLER: Instructions must remain with installation.

P/N 009132

SECTION: 6.10.070

FM1311

0309

Supersedes

0607

MODEL 507

12 VOLT DC BATTERY BACKUP PUMP

PREINSTALLATION CHECK LIST

®

© Copyright 2009 Zoeller Co. All rights reserved.

Product information presented 

here re fl ects con di tions at time 

of  publication. Consult factory 

re gard ing  dis crep an cies  or 

in con sis ten cies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

1.  Inspect your pump. Occasionally, products are dam aged during shipment. If the unit or any of the parts are dam aged, contact your dealer 

before us ing.

2.  Read all the installation instructions regarding in stall ing and start up. Retain for future ref er ence.

1.  Make sure there is a properly ground ed 115V re cep tacle avail-

 able. Do not use primary pump cir cuit. The location must be within 

6' of the control box and battery. The power supply for your DC 

control system plugs directly into the 115V outlet. DO NOT USE 

AN  EX TEN SION  CORD.

2.  Make sure the 115V electrical supply circuit is equipped 

with fuses or circuit breakers of prop er capacity.

3.  DC emergency pumps are de signed for han dling clear water. Do 

not use in septic tanks to pump ef fl u ent or sew age pits to pump 

sewage.

4.  Repair and service of your DC backup sys tem should be per formed 

by an authorized service station.

5.  The installation of DC automatic back up pumps re quires the use 

of a variable level fl oat switch for

 

operation. It is the responsibility of the installing party, to ensure 

that the fl oat switch will not hang up on the pump ap pa ra tus or 

pit pe cu li ari ties and is secured so the pump will turn “on” and 

“off”. It is recommended that the pit be 18" in diameter or larger 

to ac com mo date both a pri ma ry and a DC backup pump.

SEE BELOW FOR LIST OF WARNINGS

1.  Testing for Ground. As a safe ty mea sure each elec tri cal outlet 

should be checked for ground using an Underwriters Laboratory 

list ed cir cuit ana lyzer, which will indicate if the power, neu tral and 

ground wires are correctly con nected to your out let. If they are 

not, call a qualifi ed, licensed electrician.

2.  For your pro tec tion always dis con nect the pow er supply from 

its power source before handling the com po nents of your DC 

back up pump or the pri ma ry pump.

3.  Installation and checking of elec tri cal cir cuits and hard ware should 

be per formed by a qualifi ed, li censed electrician. 

4.  All elec tri cal and safety codes must be fol lowed in ad di tion to the 

National Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the bat tery 

and bat tery connection at least once a month. Bat-

 ter ies con tain acid and cau tion must be taken when 

han dling.

6.  Risk of electric shock - These pumps have not been investigated 

for use in swimming pool areas.

7.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and 

birth defects or other reproductive harm.

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

   Turbulence  caused  by  high  ve loc i ty  in com ing 

water can cause the DC pump to airlock. If this condition ex-

ists, the incoming water must be baffl ed to avoid ex ces sive 

tur bu lence.

Содержание Basement Sentry Series

Страница 1: ...or operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and is secured so the pump will turn on and off It is recommended that the pit be 18 in diameter or larger to accommodate both a primary and a DC backup pump SEE BELOW FOR LIST OF WARNINGS 1 Testing for Ground As a safety measure each electrical ...

Страница 2: ...Three year limited warranty valid only when a complete system is purchased and used as a backup to a primary dewatering system A complete system includes a Model 507 or 510 Basement Sentry and an Aquanot Battery 1 Inspect and test the system for proper operations at least every 3 months a Red power on indicator light should be on indicating AC power is on b Unplug primary pump and the control char...

Страница 3: ...ystem requires a good quality 12 volt battery to obtain maximum pumping time during a power outage A deep cycle 12 volt 105 amp hour marine battery or larger is recommended and will provide approximately 7 hours of continuous pumping time in a sump pump installation with 8 of head pressure In most installations the pump runs intermittently and the battery life is extended accordingly Batteries wit...

Страница 4: ...ent than the primary pump 4 If primary pump is installed disconnect power If the primary pump is a column pump with adjustable float and you are installing per figure 2 check the on point and adjust to approximately 7 from bottom of pump see figure 2 Mark the discharge pipe 7 above the on point of the primary column pump or 7 above the top of the primary submersible pump 5 If existing discharge pi...

Страница 5: ...o avoid airlocking DC PUMP PLUMBED IN LINE WITH SUBMERSIBLE PUMP OUTLET PUMP PRIMARY BATTERY BOX VERIFY WEEP HOLE IS PRESENT IN MAIN DISCHARGE LINE SEE PUMP INSTALLATION INSTRUCTIONS 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP BATTERY BOX OUTLET PRIMARY PUMP DC PUMP PLUMBED IN LINE WITH COLUMN PUMP 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN D...

Страница 6: ...D BY USER DC BACK UP PUMP CLAMP FLOAT SWITCH BLACK WITH RED TRACER TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE TO FLOAT RED LEAD 15 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH BLUE LEAD SPLICER WHITE OR PUMP ASSEMBLY 1 6 SUPPLIED BY CUSTOMER DISCHARGE PIPE TOP VIEW IMPORTANT MAKE SURE THIS LINE IS GLUED IN POINTING UP 11 18 ...

Страница 7: ...or over 7 hours and a Maintenance Free AGM Battery which will power the pump for over 3 hours These times are based on continuous pumping at 10 of static head Actual times will vary depending on static head volume of water entering the pit and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 minute reserve capacity or larger Do NOT use a maintena...

Страница 8: ...tery to the exterior Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector In no way are they meant to supersede the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer If the audible alarm associated with your CO detector is activated we recommend the following actions 1 Take imme...

Отзывы: