The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery after use when AC power 

is restored. Time for recharge depends upon the amount of power consumed by the pumping cycle during the AC power interruption. The pump may 

go back to the ready run position in a very short period of time. A completely drained battery may require up to 24 hours for full recharge. If after 24 

hours of charging the battery has not reached 6 volts, the alarm will sound and not reset until the battery is brought up to a voltage of 6.5-7.0 volts.

© Copyright 2013 Zoeller Co. All rights reserved.

MODELS:

507-C

507-D

507-E

ITEM DESCRIPTION

QTY

4/96

thru

10/05

11/05

thru

9/11

10/11

thru

Current

DC backup pump

1

010475

017198

017198

Plastic battery box

1

10-0764

10-0764

10-0764

DC control charger with terminals

1

011323

011323

011323

“Off”/”On” float switch

1

017197

017197

017197

1½" x 5" long PVC pipe nipple

1

005639

N/A

N/A

Check valve

(2) REV C - (1) REV D

005636

005636

019768

Reducer hose coupling and clamp

1

30-0188

N/A

N/A

1¼" x 1" PVC reducer fitting

1

005642

N/A

N/A

1" pipe to hose adapter elbow

1

005643

N/A

N/A

10 

1" hose coupling and two clamps

1

005703

N/A

N/A

11 

1½" PVC pipe tee

1

005645

005645

005645

12 

1½" 90 degree PVC pipe elbow

1

005644

N/A

N/A

13

1¼" x 1¼" PVC coupling

1

009129

N/A

N/A

14 

Pump mounting kit, includes brkt, S.S. worm drive clamp, two #10-

24 screws and washers.

1

005704

N/A

N/A

15

Cable tie

1

005868

N/A

N/A

16

Anchors, wall

2

009691

009691

009691

17

Bracket, control mounting

1

007779

007779

007779

18

1½" x 1½" PVC coupling

1

N/A

009746

N/A

CHECKLIST

PERFORMANCE

The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. A deep-cycle, 12 

volt, 105 amp-hour marine battery or larger is recommended and will provide approximately 7½ hours of continuous pumping time in a sump pump 

installation with 8' of head pressure. In most installations the pump runs intermittently and the battery life is extended accordingly. Batteries with top 

terminals are recommended for ease of installation. These batteries contain acid and proper precaution must be taken when handling. Maximum battery 

size 12½" Length x 7" Width x 9½" Height.

BATTERY SELECTION

Discharge

Feet of Head

5

10

15

17.5

Flow

Gal. per min.

23

15

5

Shut-off

Head

The DC pump performance with fully charged 12V battery

The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The 

DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system 

is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.

DESCRIPTION

TROUBLESHOOTING INFORMATION, 

continued

7.  Water level stays high. DC Pump continues to run.

  (a)  Battery is low.

  (b)  If power has been restored and water in sump remains high check 

primary pump. Service if required.

   (c)  After several hours the battery will be restored to full charge.

8.  Alarm sounds during battery recharge cycle.

  (a)  Push alarm reset (max. 3 times). If condition persists, replace battery.

  (b)  To silence alarm if alarm will not reset, unplug the charger from 

115V wall outlet, then disconnect the black lead from charger on 

negative (-) battery post. Check battery. Replace if necessary. 

Reconnect and refer to Installation (step 14).

Содержание Basement Sentry Series

Страница 1: ...nown to the state of California to cause cancer and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply for your DC control system plugs directly into the 115V outlet Do not use an extension cord 2 Make sure the 115V electrical supply...

Страница 2: ...warranty valid only when a complete system is purchased and used as a backup to a primary dewatering system A complete system includes a Model 507 or 510 Basement Sentry and an Aquanot Battery 1 Inspectandtestthesystemforproperoperationsatleastevery3months a Red power on indicator light should be on indicating AC power is on b Unplug primary pump and the control charger from power supply c Fill su...

Страница 3: ...A CHECKLIST PERFORMANCE The DC emergency pump system requires a good quality 12 volt battery to obtain maximum pumping time during a power outage A deep cycle 12 volt 105 amp hour marine battery or larger is recommended and will provide approximately 7 hours of continuous pumping time in a sump pump installation with 8 of head pressure In most installations the pump runs intermittently and the bat...

Страница 4: ...primary pump 4 If primary pump is installed disconnect power If the primary pump is a column pump with adjustable float and you are installing per figure 2 check the on point and adjust to approximately 7 from bottom of pump see figure 2 Mark the discharge pipe 7 above the on point of the primary column pump or 7 above the top of the primary submersible pump 5 If existing discharge pipe is metal o...

Страница 5: ...g NOTE Pump must be mounted on a 30º angle to avoid airlocking OUTLET PUMP PRIMARY 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP VERIFY WEEP HOLE IS PRESENT IN MAIN DISCHARGE LINE SEE PUMP INSTALLATION INSTRUCTIONS BATTERY BOX BATTERY BOX OUTLET PRIMARY PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN SK2499 SK2500 ...

Страница 6: ...USER FIG 5 DC BACK UP PUMP CLAMP FLOAT SWITCH BLACK WITH RED TRACER TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE TO FLOAT RED LEAD 15 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH BLUE LEAD SPLICER WHITE OR TOP VIEW IMPORTANT MAKE SURE THIS LINE IS GLUED IN POINTING UP 1 11 6 SUPPLIED BY CUSTOMER DISCHARGE PIPE ...

Страница 7: ...ance free AGM battery which can run the pump continuously for over 7 hours These times are based on continuous pumping at 10 of static head Actual times will vary depending on static head volume of water entering the pit and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 minute reserve capacity or larger Do NOT use a maintenance free battery un...

Страница 8: ...hat accompany the detector nor do they supersede advice from the CO detector manufacturer If the audible alarm associated with your CO detector is activated we recommend the following actions 1 Take immediate action for personal safety as recommended in the CO detector literature 2 Contact the appropriate agency to determine if the CO is being produced by your furnace water heater or any other dev...

Отзывы: