 STEP 

Float Stop Adjustment

  2.1)  With the pump in the pit, measure the desired fl oat stop on/off positions as shown in Fig. 2.1. These two dimen-

sions will de ter mine the on/off levels of the pump. The spacing between the upper and lower stops will de ter mine 
the amount of water removed from the pit.

 

 Note: 

It may be necessary to raise the fl oat rod guide to adjust the stops to the dimensions determined in Step 2.1.  

 

 

  The fl oat rod guide should NEVER be between the upper and lower stop.

 
  2.2)  Remove the pump from the pit and adjust the fl oat stops as necessary.  Tighten all screws.

 

Note: 

If a brick, or similar material has been used to raise the pump in the pit, it will be necessary to account for the 
thickness of the brick.

Figure 2.2

Figure 2.1

SK1776

SK1777

 STEP 

Placement of the Pump in the Pit

 Note: 

 

If your pit has a cover, then it will have to be modifi ed to accept the 

Aquanot

®

.

  1.1)  Inspect the pit for debris and clean as nec es sary

  1.2)  Place the pump in the pit making certain that it is on a stable level 

surface. Refer to Figure 1.1.

 
 

IMPORTANT:

  If this pump is to be used as a backup to your primary pump, 

then make certain that there is no interference between the two pumps.

  The motor is not watertight. It should 

NEVER 

be below fl oor level.

  If necessary, bricks or similar materials, can be placed under the 

Aquanot

®

 

  

This product is meant to be used as a battery backup pump to 

your primary pump only. Consult factory for advice before installing this unit 
as a primary pump.

Figure 1.1

SK1775

Содержание AQUANOT 585

Страница 1: ...DC automatic backup pumps requires the use of a variable level float switch for operation It is the responsibility of the installing party to ensure that the tethered float switch will not hang up on...

Страница 2: ...LORINCIDENTALDAMAGESORBREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARR...

Страница 3: ...discharge pipe smaller than the recommended pump discharge sizes 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and nati...

Страница 4: ...e the pump from the pit and adjust the float stops as necessary Tighten all screws Note If a brick or similar material has been used to raise the pump in the pit it will be necessary to account for th...

Страница 5: ...Do not put the battery monitor on top of the battery Figure 5 1 STEP 6 Testing of Pump Operation 6 1 Unplug the primary pump so that it does not start 6 2 Fill pit with water until the Aquanot starts...

Страница 6: ...Aquanot Charger Model 585 Only All Aquanot pump systems are equipped with an alarm which sounds when the pump is activated The alarm will automatically silence when the pumping cycle is completed Act...

Страница 7: ...011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 10 Adapter Drive 1 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 11 Shaft 1 01...

Страница 8: ...as depleted below 5V due to prolonged operation without AC power Call for service or replace battery F RED LIGHT FLASHING MODEL 585 The charger fan may be defective Have a qualified electrician inspec...

Отзывы: