7
1.2 I Hydraulic connections
•
The device will be connected with a Ø50 PVC pipe, using the half union connectors supplied (see § “5.1 I Description”),
to the pool's filtration circuit, after the filter and before the water treatment.
•
Respect the direction of hydraulic connection.
•
A by-pass must be installed to make it easier to work on the appliance.
: water inlet valve
: by-pass valve
: water outlet valve
: water inlet adjustment valve
(optional)
: water outlet adjustment valve
(optional)
: water treatment
* minimum distance
•
To evacuate the condensates, fit a Ø18 pipe on the grooved elbow mounted under the appliance base.
•
The elbow can be oriented at an angle of 280° beneath the appliance.
Condensate drainage elbow (view of the device from below)
Tip: condensate drainage
Caution, several litres of water can be drained from your appliance each day. We strongly recommend
connecting the drain to a suitable water drainage system.