manualshive.com logo in svg
background image

 

 

 
 
 
 
 

 

 
 
                                                 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 

 

Volume 2 

 
 

YACHTLINE  

360 / 400 

 

 

611 133  A

 

 

 

 

 
 
 
CAREFULLY READ THIS MANUAL BEFORE PUTTING YOUR ZODIAC INTO SERVICE. 

 

 

Содержание YACHTLINE 360

Страница 1: ...Volume 2 YACHTLINE 360 400 611 133 A CAREFULLY READ THIS MANUAL BEFORE PUTTING YOUR ZODIAC INTO SERVICE...

Страница 2: ...Handling 8 10 II BUOYANCY TUBE II 1 Major stages in fitting the buoyancy tube 11 II 2 Installing the buoyancy tube on the hull 12 13 II 3 Inflation system 14 II 4 Pressure 14 16 III PROPULSION SYSTEM...

Страница 3: ...n Directive 94 25 EU C Capacity YL 360 YL 400 ISO 4 5 Maximum kg 1 605 735 lb 1 1 334 1 621 kg 2 200 218 lb 2 441 481 Compartment 3 3 Engine YL 360 YL 400 Minimum recommended power HP 3 15 20 kW 3 12...

Страница 4: ...rized power with extreme caution see Recommended operating procedure chapter of Volume 1 of the manual WARNING The maximum load on the manufacturer s plate should not be exceeded The maximum load incl...

Страница 5: ...Page 5 31 E N G L I S H Seat with handles for the Yachtline 400...

Страница 6: ...60 5 seats on 400 YL 2 aft anchoring cleats 1 front polyester step with cleat navigation lights and LEDs 1 Folding and removable mast for white light 1 Deck light 3 Hinged lifting chain plates 2 Towin...

Страница 7: ...ti overflow device Navigation lights and deck lights 1 battery tray 1 battery isolation switch Pre fitted electric equipment to add extra accessories 1 Bilge pump 2 Paddles 1 Foot inflator 1 Repair ki...

Страница 8: ...Page 8 31 DESCRIPTION LOCATION OF ITEMS I 3 LOCATION OF PARTS...

Страница 9: ...ft seat 10 Towing mooring rings 11 Transom 12 Lifting rings 13 Base of white light mast 14 Aft anchoring cleats 15 Tank filling system 16 Tank maintenance access hatch 17 Bow ring 18 Buoyancy tube 19...

Страница 10: ...NDLING I 4 HANDLING I 4 1 Transport The trailer installation recommendations are specified in VOLUME I of the owner s manual I 4 2 Storage YL 360 measurements in mm WARNING The boat must rest on the b...

Страница 11: ...Page 11 31 E N G L I S H YL 400 measurements in mm WARNING The boat must rest on the bow line see sketch below...

Страница 12: ...le A B C D 360 YL m 1 25 1 1 45 1 4 ft 4 1 3 3 4 8 4 6 400 YL m 1 25 1 1 45 1 4 ft 4 1 3 3 4 8 4 6 WARNING No passengers on board while hoisting CAUTION All equipment must be unloaded from the boat fo...

Страница 13: ...ntory the parts of your boat and learn to recognize them 4 5 Inventory upon opening 6 7 Location of items 2 fit the buoyancy tube on the hull 11 Installing the buoyancy tube 3 fit the internal protect...

Страница 14: ...UNFOLDING NOTE The buoyancy tube is fitted to the hull with the buoyancy tube deflated 1 To facilitate the positioning of the buoyancy tube apply liquid soap A to the hull rails 2 A B Position the bu...

Страница 15: ...nal protective flap on the hull pull the buoyancy tube gently towards the forward section in order to send the external protective flap over the forward nose do not attach it at this point Then pull t...

Страница 16: ...er is up The membrane is open the plunger is down BUOYANCY TUBE PRESSURE INFLATING THE ENGINE Place all the valves in the inflation position Attach the hose connector to the inflation pump inflation p...

Страница 17: ...ew on the inflation valve plugs NOTE A slight loss of air is normal before the cap is screwed on Only the plugs provide final airtightness BUOYANCY TUBE PRESSURE CORRECT PRESSURE The correct pressure...

Страница 18: ...p in pressure at the end of the day when the outdoor temperature drops RISK OF OVERPRESSURE EXAMPLE Your boat is inflated to its recommended pressure 240 mb 3 4 PSI at the beginning or end of the day...

Страница 19: ...19 31 E N G L I S H PROPULSION SYSTEM III Propulsion system Comply with Zodiac s recommendations and with the engine manufacturer s recommendations For optimal use of your boat please consult your de...

Страница 20: ...mitter 7 Overflow compartment 8 Filler cap with integrated vent 9 Tank maintenance hatch WARNING It is vital to have a gauge dial It is supplied with the engine If your boat does not have one contact...

Страница 21: ...partition REF DESCRIPTION 1 Filter head secured to boat 2 Replaceable filter cartridge 3 Metal bowl 4 Purge screw WARNING Doing so could damage the seal and compromise the tightness of the bowl NOTE M...

Страница 22: ...EFORE EACH OUTING PREVENTS CONDENSATION FROM FORMING HAVE THE TANK CLEANED EVERY 5 YEARS Check that all hose clamps are tight When you drain the filter do not empty the water into the boat Place a rec...

Страница 23: ...Page 23 31 E N G L I S H INSTALLATION AND CIRCUIT ELECTRICITY IV 2 ELECTRICAL DIAGRAM...

Страница 24: ...arging the battery always remove it from the engine compartment Battery electrolyte is a toxic and dangerous liquid It contains sulphuric acid which can cause serious burns Avoid contact with skin eye...

Страница 25: ...ION of options IV 4 STORAGE OF NAVIGATION LIGHT MAST WARNING To not damage the navigation light mast when closing the seat always stow it as shown on the photo above NOTE To facilitate fitting the mas...

Страница 26: ...max WARNING You must make sure that the total power of the accessories you add in column A is 180 W 15 A or less AND that the max power of an accessory in column B is 72 W 6 A or less The cross sectio...

Страница 27: ...equipment 20 W clock Depth sounder Shower pump GPS 36 W Max power 20 W 72 W Searchlight Alarm system Refrigerator VHF 72 W 168 W 180 W CONCLUSION Example 2 You want to add A 60 W VHF A 36 W GPS A 48...

Страница 28: ...the power IV 5 2 Wiring Choose a free fuse location Connect the power supply of your accessory to the terminal corresponding to this slot using a 6mm female tab type terminal lug If you have to add ca...

Страница 29: ...operates independently the control switch is always ON Automatic operation set position in this position the bilge pump operates automatically The indicator light is on Off in this position set positi...

Страница 30: ...e elements should be installed in compliance with the relevant requirements of ISO 6185 3 to ensure that all such installations do not invalidate the initial assessment Also ensure that the subsequent...

Страница 31: ...31 E N G L I S H Z NAUTIC GROUP 2 chemin de la Val Priout 31450 AYGUESVIVES FRANCE YACHTLINE 360 400 Copyright Z NAUTIC Z NAUTIC S A S U with capital of 7 095 000 00 Euros Toulouse Trade Register 812...

Отзывы: