6. STARTING UP
* Technical characteristics:
* With ambient air at + 15°C and pool water at 24°C – NC = Not Communicated
•
Appliance protection index:
IP 24
.
•
Refrigerant gas type:
R410A
.
• Manufacturer's gas fill value
:
EdenPac 2 1-ph. =
850 g
. - EdenPac 3 1-ph. =
1300 g
. - EdenPac 4 1-ph. =
1600 g
.
EdenPac 5 3-ph. =
1500 g
. EdenPac 6 3-ph. =
3000 g
.
* Heat pump operating conditions:
• The outside temperature must be higher than +5°C
(automatic shut-off by anti-frost sensor SD2)
and below +38°C.
• A sufficient water flow must pass into the heat pump.
Note:
The heat pump stops heating the pool when it starts a defrost cycle and interrupts the compressor and ventilation
systems, according to the information provided by the defrost sensor SD3 which is factory-set to -10 °C in the
refrigeration circuit. When this temperature increases to 12 °C, the fan switches off and a 120 to 300 second time period
starts
(depending on the compressor stoppage time)
before the fan and compressor restart simultaneously.
?
Possible
traces of humidity
at the base of the unit may be due to
|
normal
condensation of the water vapour in
the air or due to the defrost cycle in progress
(phenomenon visible if
the additional condensation evacuation kit
is not used)
.
6.1 Check
•
that the hydraulic connections are correctly tightened.
• that there is no water leak.
• that the appliance is stable (with a level gauge and spirit level).
• that the cables are correctly connected to their terminals.
?
Incorrectly tightened cables may cause overheating of terminals
.
• that the cables cannot be damaged by sharp metal sheets or elements.
• the earth connection.
• that no tools or other objects have been left inside the appliance.
Appliance
Power
consumption *
Power
restored *
Rated
current
consumption*
Max.
current
consumed
Acoustic
power
Acoustic power
at 10 m
Net
weight
EDENPAC 2
Single phase
2.04 kW
10 kW
9.8 A
15 A
66.5 dBA
38.5 dBA
87 kg
EDENPAC 3
Single phase
2,42 kW
12 kW
13 A
16 A
66,5 dBA
38,5 dBA
90 kg
EDENPAC 3
Three phase
2,46 kW
12 kW
5,8 A
7 A
NC NC
90 kg
EDENPAC 4
Single phase
3,15 kW
15 kW
15,2 A
19 A
NC NC
94 kg
EDENPAC 5
Three phase
3,22 kW
16 kW
6 A
9 A
70 dBA
42 dBA
99 kg
EDENPAC 6
Three phase
4,02 kW
21 kW
7 A
11 A
71,5 dBA
43,5 dBA