background image

 1 

 

 

CONTENTS 

 

 

 

 
 1 

General.................................................. 2 

 
 

 

 

  1.1 General terms of delivery .............................. 2 

   

 

1.2 

Voltage .......................................................... 2 

   

 

1.3 

Water 

treatment ............................................. 2 

 

 2 

Description............................................ 2 

 
   

 

2.1 

Presentation ................................................... 2 

 

 

 

   

2.1.1 Edenpac 2, 3, 4 and 5 

   

 

  2.1.2 

Edenpac 

   

 

2.2 

Dimensional 

characteristics........................... 5 

 

 

 

   

2.2.1 Edenpac 2,3, 4 and 5 

   

 

  2.2.2 

Edenpac 

 

 3 

Installation ............................................ 7 

 

 4 

Connections .......................................... 9 

 
 

 

 

4.1 Access to the electrical card ............................. 9 

 

 

 

   

4.1.1 Edenpac with single fan 

 

 

 

   

4.1.2 Edenpac with double fan 

 

 

 

4.2 Hydraulic connections ...................................... 10 

 

 

 

4.3 Electric connection ........................................... 11 

 

 

5 Regulator operation ............................. 12 

 
   

5.1 

Presentation ...................................................... 12 

 

 

 

5.2 Setting the target temperature........................... 12 

 

 

6 Starting up ............................................ 13 

 
   

6.1 

Check................................................................ 13 

 

 

 

6.2 Start up the heat pump ...................................... 14 

   

6.3 

Checking........................................................... 14 

 

 

 

6.4 Fault and state display ...................................... 15 

   

6.5 

Winter 

storage .................................................. 16 

 

 

7 Maintenance instructions .................... 16 

 

 

8 Recycling the product .......................... 16 

 

 9 

Electrical 

diagrams .............................. 17 

 
   

9.1 

Electrical 

diagram of connection  

 

 

 

     Interface card.................................................... 17 

   

9.2 

Electrical 

diagram EdenPAC single-phase ....... 18 

   

9.3 

Electrical 

diagram EdenPAC three-phase......... 19 

 

 

 

 

Содержание Edenpac 2

Страница 1: ...gle fan 4 1 2 Edenpac with double fan 4 2 Hydraulic connections 10 4 3 Electric connection 11 5 Regulator operation 12 5 1 Presentation 12 5 2 Setting the target temperature 12 6 Starting up 13 6 1 Ch...

Страница 2: ...2 Voltage Prior to any operation check that the voltage on the name plate of the appliance corresponds to the mains voltage provided on site 1 3 Water treatment In order to use our appliances under th...

Страница 3: ...ANIUM condenser unit 8 Regulator sensor 9 LP pressure switch Cased SCROLL compressor 11 Arched flat fin unit cooler 12 Anti frost sensor 13 Fastening plates with silent blocks 14 Pool inlet water conn...

Страница 4: ...e on photos but located at the back of the unit 1 2 3 4 6 5 7 8 9 11 13 1 Top and bottom panels with polypropylene grid 2 Motor fan unit 3 Access flap to digital regulator 3a Euro FK and pressure gaug...

Страница 5: ...ions of the appliance with packaging in mm Weight of Edenpac 2 with packaging 98 kg Weight of Edenpac 3 with packaging 101 kg Weight of Edenpac 4 5 with packaging 110 kg 1275 480 870 To be transported...

Страница 6: ...6 2 2 2 Edenpac 6...

Страница 7: ...anner 13 1 ratchet spanner 1 pliers 2 straps for handling Choose the appliance installation site according to the following criteria the appliance must be installed outdoors the clearance around the a...

Страница 8: ...re are not water jets In the contrary case respect a minimum distance of 3 5 metres Attention Do not lift the appliance by picking it up at the front and or the water inlet outlet points Use 2 lifting...

Страница 9: ...crews 2 and 3 on the right side using a cross head screwdriver Slide the entire front panel forward and then down 4 1 2 Edenpac with double fan Turn the 2 clips 1a and 1b in the front turn clockwise u...

Страница 10: ...ent facility see diagrams below Hydraulic circuit test pressure 3 bar Hydraulic circuit operating pressure 1 5 bar Edenpac 2 3 4 and 5 Average water flow 5 to 6 5 m3 h pressure drop 1 3 to 1 7 mCE 0 1...

Страница 11: ...olarity 230V 50Hz between terminals 1 2 refer to the electrical wiring diagram below Possibility to connect an exterior fault indicator of 230V 50Hz between terminals 0 and 4 refer to the electrical w...

Страница 12: ...f the water temperature becomes or is lower than the target temperature the regulator unit authorises heating after a set time of 180 seconds the Led blinks and then remains on 5 2 Setting the target...

Страница 13: ...at the base of the unit may be due to normal condensation of the water vapour in the air or due to the defrost cycle in progress phenomenon visible if the additional condensation evacuation kit is not...

Страница 14: ...d longer than or equal to 3 s a timer of 130 seconds min is activated before the unit starts again For information this time period may increase during a defrost cycle or if the compressor stop time i...

Страница 15: ...ne hour Consult a PSA approved technician to check the sensor and operation of the defrost cycle Cut power supply or press the button if dtd starts blinking after stand by Ofr5 and switch the regulato...

Страница 16: ...g operations must be carried out at least once a year Clean the evaporator at the back of the heat pump with a soft brush and gentle water spray Never use a high pressure cleaner for this operation Ch...

Страница 17: ...17 9 ELECTRICAL DIAGRAMS 9 1 Electrical diagram of connection interface card To J11 and J12 To J6 and J14...

Страница 18: ...18 9 2 Electrical diagram EdenPAC single phase IMPORTANT Elimination or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE...

Страница 19: ...19 9 3 Electrical diagram EdenPAC three phase IMPORTANT Elimination or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE...

Страница 20: ...or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE With an aim to improving its products PSA reserves the right to modify the characteristics without prior...

Отзывы: