H0369400.B.EN
–
2013/03
5
2.3.2
Power
supply
connection
to
the
AquaLink
TRi®
control
box
The
AquaLink
TRi®
control
box
has
its
own
power
supply.
It
must
be
permanent
and
protected
by
a
30
mA
ground
fault
circuit
breaker.
Please
refer
to
the
wiring
diagram
§2.3.1.
The
use
of
a
30
mA
Residual
Current
Device
with
a
manual
switch
(=
RCD)
is
mandatory
to
protect
the
AquaLink
TRi®
mains
supply.
It
must
be
accessible
at
any
time
by
anybody
who
needs
to
access
to
the
unit.
2.3.3
Connection
to
the
filtering
pump
relay
On
the
"FILTER
PUMP"
relay
connect:
the
permanent
power
supply
to
terminals
'Line
1"
(live)
and
"Line
2"
(neutral).
This
power
supply
must
be
protected
upstream
by
an
appropriate
ground
fault
circuit
breaker
and
fuse.
the
power
supply
cable
for
the
filtering
pump
to
terminals
"Load
1"
(live)
and
"Load
2"
(neutral).
2.3.4
Connecting
auxiliary
equipment
Connect
to
relays
"AUX1",
"AUX2"
and
"AUX3":
the
permanent
power
supply
to
terminals
'Line
1"
(live)
and
"Line
2"
(neutral).
This
power
supply
must
be
protected
upstream
by
an
appropriate
ground
fault
circuit
breaker
and
fuse.
the
power
supply
cable
for
the
equipment
to
be
controlled
to
terminals
"Load
1"
(live)
and
"Load
2"
(neutral).
The
"AUX1",
"AUX2",
and
"AUX3"
relays
are
free
to
be
used
to
control
any
electric
equipment
compliant
with
the
capacities
shown
on
the
wiring
diagram
§2.3.1
(for
example
a
booster
pump,
a
lighting
transformer,
an
extra
pump
for
a
water
feature
or
a
backwash,
garden
lighting,
etc.)
Do
not
connect
multiple
items
of
equipment
to
the
same
relay.
The
relays
can
also
be
used
as
switches
for
equipment
with
an
external
electric
power
supply
that
only
require
a
low
voltage
"on
‐
off"
contact
command.
In
this
case
only
use
one
side
of
the
relay:
"Line
1"
/
"Load
1"
or
"Line2"
/
"Load
2".
2.4
Low
voltage
electric
connections
Low
voltage
connections
have
a
reserved
area
on
the
right
of
the
AquaLink
TRi®
control
box.
You
can
connect:
-
1
air
temperature
sensor
(installed
at
the
base
of
the
control
box)
-
1
water
temperature
sensor
(supplied)
-
1
"RS485"
cable
from
the
iAquaLink™
antenna
‐
box
(supplied)
And
optionally
(not
supplied):
-
1
solar
temperature
sensor
-
1
heating
system
control
cable
-
1
"RS485"
TRi®
salt
water
chlorinator
control
cable
-
1
"RS485"
cable
for
any
other
iAquaLink™
compatible
equipment
2.4.1
Air
temperature
sensor
connection
The
air
temperature
sensor
is
pre
‐
wired
and
placed
at
the
base
of
the
AquaLink
TRi®
control
box.
It
is
imperative
that
it
measures
outside
air
temperature,
and
it
must
be
sheltered.
If
the
control
box
is
installed
inside,
the
temperature
sensor
must
be
installed
remotely:
-
remove
the
sensor
from
the
control
box
with
its
5
metre
cable,
-
fix
the
sensor
outside,
under
a
shelter,
using
the
supplied
fixture
clip.
The
air
temperature
sensor
is
especially
useful
in
managing
the
anti
‐
freeze
safety
device.
Zodiac®
cannot
be
held
liable
for
damage
caused
to
the
pool
related
to
the
incorrect
location
of
the
air
temperature
sensor.
2.4.2
Water
temperature
sensor
connection
A
sensor
is
designed
to
measure
water
temperature
and
control
the
pool
water
heating
system.
It
is
supplied
with
a
5
metre
cable
(see
§1.2).
The
water
temperature
sensor
must
measure
the
temperature
before
the
heating
system.