POWER PACK
TO COMMON
POWER SOURCE
HEATER
CHECK VALVE
FILTER
CELL
INTAKE
The cell must be installed
as the last piece of equipment in
the circulation plumbing system
just before the pool.
RETURN
WATER FEATURE /
IN FLOOR CLEANER
Section 2. General Description
Figure 1.
Example of Installation
2.1
Product Specifications
Maximum Operating Pressure: 50 psi
Input Freq: 60 Hz
Minimum Flow Rate: 76 lpm (20 gpm)
Output Voltage: 25V DC (max)
Required Salt Level: 3.0 gpl (3,000 ppm)
Dimensions:
Power Pack (L x W x H):
25.4 cm x 11.4 cm x 33 cm (10 in. x 4.5 in. x 13 in.)
Electrolytic Cell (L x W x H):
16.5 cm x 14 cm x 30.5 cm (6.5 in. x 5.5 in. x 12 in.)
Maximum water volume treated:
132,000 L (35,000 gal.)
Chlorine Output:
0.42 kg (0.93 lbs) per day
Input Voltages: 240 VAC
Weight:
Power Pack: 3.2 kg. (7 lbs)
Electrolytic Cell: 0.9 kg (2 lbs)
Input Current @ 240 VAC: ~1 A
PUMP
Page 6
ENGLISH
Jandy
®
Pro Series TruClear
™
Chlorine Generating System
|
Installation & Operation Manual