Zodiac Pool Systems DuoClear 200 Скачать руководство пользователя страница 16

DUOCLEAR START UP PROCESS

14

Before starting up the DuoClear system you must add the required amount of salt
for your size pool. (Refer to Salt Chart on page 25). Do not operate the DuoClear
until the salt has dissolved and a 3200-4000 ppm salt level has been attained.

Clean any debris and algae out of the pool and pool equipment before start up.

IMPORTANT: Do not start the DuoClear system until the pool water is chemically balanced.
See Water Chemistry Readings on page 11.

1.  Install the cartridge.

2.  Balance the water. 

3.  Shock the pool water with chlorine according to manufacturer’s instructions to burn off

contaminants and activate the cartridge.

NOTE: This is not the same as the Superchlorinate feature on the DuoClear system. A
manual shock treatment is required at start-up to activate the cartridge.

4.  Turn on the DuoClear system. Press the Nature2 Reset button to start the cartridge timer,

which will count down 6 months to the next cartridge change.

5.  Run the circulating pump either 24 hours a day for 4 days, or 6 hours a day for 14 days,

while maintaining 1-3 ppm of free available chlorine.

NOTE: To properly charge battery and insure proper start up, DuoClear must be run 24
hours per day for 4 days when the unit is first installed.

6.  Let chlorine gradually dissipate to 0.6 ppm once the circulating period is completed.

NOTE: If the temperature is below 18°C (65°F) you may not be able to set the output to
maximum because of a slight reduction of conductivity in colder temperatures (the Add Salt
light may also come on). When the water is below 18°C (65°F), there is very little algae growth
and it is too cold for swimming so the chlorine does not get used up as much as it would during
normal operating conditions. If this is the case, you can leave the DuoClear at a lower output
setting until the temperature warms up.  

WARNING: Never allow the concentration of free chlorine to go below 0.6 ppm. If this is not
possible with the DuoClear system, use a manual application of liquid chlorine (sodium
hypochlorite).

Содержание DuoClear 200

Страница 1: ...ATING SYSTEM FOR SWIMMING POOLS DOMESTIC REGISTRATION NUMBER 28212 PEST CONTROL PRODUCTS ACT TO THE BUILDER PLEASE LEAVE THIS MANUAL WITH POOL OWNER TO THE POOL OWNER PLEASE SAVE THIS MANUAL PLEASE RE...

Страница 2: ...icidal activity of the primary disinfectant chlorine Maximum output of hypochlorous acid equivalent to 0 816 kg of free available chlorine per day One DuoClear 200 can treat an outdoor swimming pool t...

Страница 3: ...ures of the DuoClear System 12 DuoClear Start up Process 14 Using the Control Panel Operating Functions 15 DuoClear Cartridge and Electrode Life 17 DuoClear Maintenance 18 Operating Hints 21 Salt When...

Страница 4: ...tem without water circulation Power supply must be synchronized with the pool pump motor power source or automatic timer To reduce the risk of electric shock the DuoClear should be grounded ELECTRICAL...

Страница 5: ...they may damage any surface in which they come in contact The addition of certain chemicals can reduce the effectiveness of chlorine Always make sure that proper residual chlorine levels are maintain...

Страница 6: ...em with a pool pump that has a built in timer as this does not allow for proper synchronization with the salt system If this is a retro fit installation with an existing pump that has a built in timer...

Страница 7: ...s expertise to swimming pools to bring you a full range of pools automatic pool cleaners and water treatment systems Backed by Nature2 and Clearwater technology expertise and experience Zodiac brings...

Страница 8: ...ion This owner s manual will provide you with useful information on how to operate the DuoClear system most efficiently and help you to understand more about the maintenance of your pool Your local po...

Страница 9: ...mensions 28 cm x 15 cm x 28 cm 11 x 6 x 11 Power pack dimensions 29 cm x 9 5 cm x 25 4 cm 111 2 x 33 4 x 10 DUOCLEAR COMPATIBILITY DuoClear Systems can be used with all types of pool chemical treatmen...

Страница 10: ...temperature and correct mains voltage will provide maximum output If any one or more of these three variables are less than the standard values the output may be less NOTE We recommend waiting 2 4 wee...

Страница 11: ...ST be plumbed on by pass A control valve must be installed to regulate the flow through the vessel It can be installed on the inlet side of the vessel or between the inlet and discharge side of the ve...

Страница 12: ...is powered on Any other type of installation will void the warranty Connect power supply wires to the two terminals as indicated on the wiring diagram It does not matter which of the two terminals bu...

Страница 13: ...to the dissolved salt ion chloride and the process is repeated IMPORTANT To ensure your DuoClear system works at maximum efficiency regularly check and maintain the water chemistry of your pool WATER...

Страница 14: ...l filtration system should be run continuously for 24 hours Add Salt 3 indicator yellow light indicates when more salt is needed Before adding salt check the salt level in the pool with a salt test st...

Страница 15: ...ce it is set The polarity of the electrodes periodically reverses in order to minimize scaling on the electrode plates This reduces manual cleaning time however depending on the pool water chemistry y...

Страница 16: ...count down 6 months to the next cartridge change 5 Run the circulating pump either 24 hours a day for 4 days or 6 hours a day for 14 days while maintaining 1 3 ppm of free available chlorine NOTE To p...

Страница 17: ...of the pool water Or take a water sample to your pool shop for testing During polarity reversal the yellow light flashes The yellow minimum output light will flash for a few minutes when the electrod...

Страница 18: ...n off at this time See Troubleshooting The green Chlorine Output indicator lights will also turn off at this time NATURE2 CARTRIDGE INDICATOR LIGHTS 5 A series of 4 lights indicate the life of the Nat...

Страница 19: ...closed for the winter the cartridge must be replaced at the beginning of each spring Even if the cartridge is only used for 3 months during the first year the cartridge must be replaced the next spri...

Страница 20: ...GE 1 Turn off the pool pump and release the pressure in the system 2 If appropriate close any valves between the filter and pool to prevent draining the pool 3 Unscrew the cartridge locking ring and r...

Страница 21: ...in a well ventilated area Use caution when choosing a location to open and use chemicals as they may damage any surface into which they come in contact 5 Mix cleaning solution in a suitable plastic v...

Страница 22: ...licone grease 9 Reset valves and switches Turn pump and chlorinator on 10 Confirm chlorine output and settings on the power pack Your DuoClear system has been designed with an electronic flow sensor T...

Страница 23: ...al climate Extremely hot and sunny climates will require readings at the higher end on the given range Refer to the Stabilizer Chart Cyanuric acid prevents rapid destruction of chlorine by the sun s r...

Страница 24: ...iluting the pool water with fresh water Do not add pool chemicals directly to the skimmer This may damage the electrode G SPRING START UP The output of the electrode is determined by water temperature...

Страница 25: ...DUOCLEAR COMPATIBILITY DuoClear Systems can be used with all types of pool chemical treatments available except bromine and bromide based chemicals biguanide products and copper based algaecides IMPO...

Страница 26: ...or you may not need to run the DuoClear at all HOW MUCH TO ADD Use a salt test strip to determine the salt level in pool water prior to adding any salt Capture water from elbow depth in a container t...

Страница 27: ...as this will cause damage to the unit Be conservative when adding salt as it is easier to add more if needed than it is to dilute if there is too much salt 0 10 20 30 40 50 STABILIZER CYANURIC ACID CH...

Страница 28: ...OTAL ALKALINITY AFFECTS pH Total alkalinity is a measure of the alkaline chemicals in your pool water e g bicarbonates carbonates and hydroxides It can be thought of as the buffering system necessary...

Страница 29: ...ning a residual chlorine level to prevent future algae growth With extreme algae conditions manually shocking the pool is the best option NOTE Overuse of algaecides can lead to a reduction in chlorine...

Страница 30: ...it This will void the DuoClear no stain warranty 5 Backwash the filter 6 Drain part of the pool water The amount to drain varies from one part of the country to another Consult your dealer for advice...

Страница 31: ...6 See Some Tips on Water Chemistry III Press the button marked Super Chlorinate The DuoClear automatically increases its output and runs for approx 24 hours of pool pump time IV After 24 hours backwas...

Страница 32: ...ine demand PROBLEM C CHLORINE ODOUR CAUSE Presence of excess chloramines combined chlorine Surprisingly the problem here is not too much chlorine as many imagine Chloramines form by the bonding of chl...

Страница 33: ...wired properly but incoming voltage is low due to location rural areas for example raising the salt level will compensate If adding salt to compensate for low voltage do not exceed 5000 ppm of salt a...

Страница 34: ...e end of its life REMEDY Replace electrode Use only replacement electrodes having a label that clearly states that it is a replacement electrode for the DuoClear 200 CAUSE 6 Electronics malfunctioning...

Страница 35: ...ower to unit If fuse continues to trip contact Zodiac Pool Care Canada Ltd at 1 888 647 4004 CAUSE 3 Component failure within power pack REMEDY Call Zodiac Pool Care Canada Ltd 1 888 647 4004 PROBLEM...

Страница 36: ...f this manual within 30 days Replace the Nature2 cartridge every six months or at every spring opening Each time a cartridge is purchased submit a copy of the proof of purchase receipt along with a cu...

Отзывы: