background image

Zodi Hut

Enjoy privacy anywhere 
with this self supporting 
shelter. Extra big almost 
4 feet per side.

12 Volt Pump

Get a back-up 12 volt 
pump. Great for outfitters 
& cabins. Works with all 
Zodi heaters. 

Camp Sink

Enjoy a collapsible camp 
sink on your next adven-
ture. Oversized to soak 
pans and plates.

Zodi Shower Pole

Enjoy hands free 
showering. Adjustable 
height. Works with all
Zodi showers and Huts.

Garden Hose Adapter

Connect your Hot Tap 
Shower to any garden 
hose without using your 
pump or batteries.  

����������������������������������������

Congratulations!  You have just purchased the BEST Instant water heater and portable hot shower available. To 
ensure safety and to get the most performance from your new portable hot shower system, please read and fol-
low these directions. These directions are for the X-40 series and may reference options not found on your model. 
Please register your warranty within 10 days of purchase at www.zodi.com.

12 volt pump

propane 
regulator

��������������������������

��������������������

������������������������

�������������������������������

�������������������

���������������

�������������������������

���������������������������

������������������

Low Water Pressure:

   Low water pressure is usually due to the 

power supply delivering less then 12 volts. Other common low 

water pressure problems include kinked hoses, vapor locked 

hoses, plugged pump or the shower head being to high above 

pump.

12 Volt Power:

   Check that pump is connected to a good 12 volt 

power source (battery or generator). Voltage below 12 volts will 

cause the water flow to be reduced.

Kinked Hoses:

   Check that pump hose and shower hose 

are not kinked. Squeeze kinks from all hoses before use. Do not 

use system with kinked hoses.

Vapor Lock:

   If pump is workin

����

he hoses are not kinked, and 

water is still not spraying from the shower head, your system is 

vapor locked.  Vapor lock can be released by applying suction to 

the shower head while pump is on and submerged in water

(Heater must be off).

Plugged Pump:

   Occasionally the pump will get plugged with 

debris in the water - remove pump cap and clean out input area.

Shower Head Height:

   The shower hose is 16 feet long for con-

venience around camp. For best water flow keep shower head 6 

feet or less above pump. To increase water flow reduce elevation 

between showerhead and pump.

Gear Bag as Water Container:

   If using padded gear bag as 

a water container, it is necessary to first position plastic bag 
inside gear bag to hold water. Position pump inside plastic bag 
with suction end of pump away from plastic bag to prevent 
pump from attracting loose plastic bag around suction end of 
pump, which may restrict water flow.

Low Water Temperature:

   Several factors contribute to cool 

water temperatures. The most common is a low or empty 

propane tank. For best performance use a full propane tank  

stored at room temperature. High water flow or wind also reduce 

water temperatures.

Check Propane Source:

   The X-40 is designed to operate with 

a full propane tank stored at room temperature. If propane source 

is low or if the propane temperature is very cold, the X-40 heater 

will not heat as hot as normal and it may be needed to recirculate 

water.

Wind & Altitude:

   The X-40 is designed to operate in low wind 

conditions and below 5,000 feet. For best performance, safely 

shield X-40 from wind. Above 5,000 the X-40 may not heat as hot 

as normal and it may be needed to recirculate water. 

Re-circulate Water:

   The X-40 is able to instantly provide hot 

water regardless of how cold the water source is, but sometimes 

recirculating the water is helpful. To recirculate water,  place the 

recirculating the water is helpful. T

recirculating the water is helpful. T

showerhead and pump in a water container with 5 - 20 gallons 

of water. Turn on the pump and then the heater. In just a few 

minutes the water spraying from the shower head will be a com-

fortable temperature. By recirculating the water you are able to 

still enjoy hot water with a cold or near empty propane tank or at 

higher altitudes. Do not heat water over 100° or injury may result. 

Follow directions found on page 4.

Condensation:

   The water dripping from the bottom of the Hot 

Tap during use is normal and will occur every time heater is on.

W

ater must be flowing from X-40 showerhead before igniting propane burner.

Water must always be flowing from X-40 showerhead when propane burner is on.

If water flow drops or water temperature increases, immediately point showerhead away from body and safely turn off 
heater until water pressure is regained. CAUTION - water may be hot when water pressure is regained - keep clear of 
showerhead until desired water temperature is obtained.

Do not heat water over 100°F. System is not designed to heat water for human consumption.

Do not use indoors. The X-40 heater, like all propane systems emits deadly carbon monoxide fumes when operating. 
Designed for outdoor use only. Improper use can result in injury or death. 

Allow X-40 heater to completely cool before handling or storing & transport. Turn off gas valve on propane tank & discon-
nect regulator from propane tank between uses.

For best performance, shield system from wind and use propane tanks stored at room temperature.

In cold climates remove pump from water source and purge hoses with air after each use. 
(To prevent damage to heating coil from freezing.)

Do not heat in confined areas. Heat only outside in well ventilated areas. Do not operate near any combustible sources. 
Position propane tank clear of all heat sources. Do not store items on top of X-40. Keep clear of top and bottom covers 
and housing during ignition and operation. Housing is HOT, do not touch.  

Adjust water temperature with gas control knob located on front of X-40 near bottom of panel. If water is too hot reduce 
gas flow using propane valve. If water is not hot enough, increase gas flow using propane valve on front of X-40 or recy-
cle water as defined on page 2. If using optional Garden Hose Adapter adjust water flow to 1 gallon or less per minute. 
Water flows above 1 gallon per minute may result in lower then desired water temperatures. 

If ignitor fails replace AA battery (tip end inserts first). If battery fails in field, place lit match through manual ignition hole 
on back of system then turn on gas valve.

If using padded gear bag as a water container, it is necessary to first position plastic bag inside gear bag to hold water. 
Position pump inside plastic bag with suction end of pump away from plastic bag to prevent pump from attracting loose 
plastic bag around suction end of pump, which may restrict water flow.

WARNINGS & CAUTIONS

Zodi options and upgrades for your X-40 Shower...  see now at www.zodi.com    

pat. pend

©

061704

©

061704

������������

������������

(tank not included)

retractable 
legs

gas valve

Instant Ignition
(needs AA)

carry handles

shower hose
& showerhead

top cover

register warranty at www.zodi.com within 10 days of purchase

register warranty at www.zodi.com within 10 days of purchase

Meijer.com