SET-UP

1. Select a clear flat area outdoors in well ventilated area away from flammable material. Remove heater, hoses & pump from gear bag. 
2. Extend support legs by depressing button in leg bracket and twist legs downward until secure. Repeat for all 4 legs.
3. Securely connect propane regulator to 5 gallon propane tank. Securely position propane tank away from heater. Leave valve on propane tank in “OFF” 
position. Check that Propane Valve on front of X-40 is also in the “OFF” position (Knob points to left and is locked). 
4. Uncoil shower hose and secure showerhead in desired location. Check that shower hose and pump hose are free of kinks. Attach pump to hose.
5. Submerge 12 volt water pump in water. Connect pump to 12 volt power source. Water will flow from the showerhead. 
6. Test instant ignitor by pushing ignitor button - you should be able to hear ignitor sparking (DO NOT TURN ON GAS VALVE). If ignitor is not sparking, 
twist off ignitor cap and add AA battery - tip end inserts first, reattach cap and depress button.
7. If using padded gear bag as a water container, it is necessary to first position plastic bag inside gear bag to hold water. Position pump inside plastic bag 
with suction end of pump away from plastic bag to prevent pump from attracting loose plastic bag around suction end of pump, which may lower water flow.

not proceed until

HEATING 

1. CAUTION - WATER MUST BE FLOWING FROM SHOWERHEAD BEFORE IGNITING AND AT ALL TIMES WHEN HEATER IS ON. Heat OUTDOORS 
only in well ventilated area. Turn propane tank gas valve to the “ON” or “OPEN” position. Ensure gas regulator is tight where connected to propane 
tank and is not leaking gas.
2. On the X-40 control panel “Push in” the Propane Valve & turn left (so knob points down) while pushing in and holding the ignitor button for 5 seconds. 
During ignition it is important to have ignitor depressed and sparking when gas valve is turned on. Keep hands, face, arms and clothing away from top and 
bottom of X-40 shower during and after ignition. Always keep top of X-40 heater clear at all times. 
3. Feel for HOT air rising from top X-40 heater. If still cool, DO NOT RE-IGNITE. Shut off Propane Valve, wait 1 minute and repeat step 2. If system still fails 
to ignite, replace AA battery in ignitor by twisting ignitor cap off, (insert AA battery tip first) or place lit match in hole on side of heater while turning on gas 
valve.  
4. During heating periods you will see water dripping from bottom of heater - this is condensation and will occur every time the heater is on. Leaking will not 
be present before igniting heater, but will occur when heater is on. Heater is NOT leaking, this drip is normal.
5. CAUTION - housing gets very hot when heating - keep clear at all times when heating.  Do not operate unattended. Do NOT ignite or operate heater 
without water flow - water must be freely flowing from showerhead whenever heater is on.

SHOWERING

1. To change water temperature adjust Propane Valve knob on X-40 control panel. Changes will take about 30 seconds to be noticed at showerhead. Do 
NOT heat water over 100ºF.  The shower hose is extra long so you can stand a safe distance away from the X-40 heater during showering periods. Never 
have the shower hose so taut that it may kink or cause the X-40 heater to tip over. If water is not hot enough, turn gas valve to full on (knob points down) or 
recirculate water as described on page 2. If water is too hot reduce gas flow by turning gas valve knob slowly to left.
2. If water pressure suddenly drops, immediately turn showerhead away from body, safely turn off heater and allow X-40 heater to cool. Inspect the hoses 
for kinks and check pump. Ignite heater only AFTER proper water flow has been regained. Stay clear of initial water flow - it may be hot after re igniting. 
3. Never turn off water flow when heater is on. Water must ALWAYS freely flow from showerhead when heater is on. Never use non factory showerhead or 
shower hoses. NEVER restrict water flow when heater is on. Do not modify or change showerhead or shower hose in any way.
4. X-40 is now ready for showering - for added convenience see accessories including the zodi shower shelter and shower pole at www.zodi.com.

SHUTDOWN

1. To shutdown, turn off propane gas valve on the X-40 control panel (point and locks in left position) and allow water to continue flowing for 30 seconds. 
2. Allow system to cool before handling or storing. 
3. After system has cooled position X-40 in covered area to protect system from rain or snow.
4. Drain water from hoses and heating coil. 
5. Turn propane valve on top of gas cylinder to “OFF” and remove X-40 regulator from propane tank between uses. 
6. In cold environments purge hoses and coil with air to prevent freeze damage. 
7. Remove gas cylinder prior to transport. 
8. Retract legs and coil hoses before placing in storage bag. Use caution as to not kink shower hose or pump hose when placing in storage bag. Prevent 
damage to storage bag and other gear by wrapping X-40 with towel and placing inside plastic bag before storing in gear bag.

CAUTION: Improper use can result in injury or death. Zodi LLC not responsible for improper use.

PLEASE REGISTER YOUR PRODUCT AT WWW.ZODI.COM WITHIN 10 DAYS OF PURCHASE OR WARRANTY MAY BE VOID.

register warranty at www.zodi.com within 10 days of purchase