DIRECTIONS - FOLLOW THESE DIRECTIONS AT ALL TIMES.

Read, understand and follow the instructions printed in this instruction manual, printed on the product, and on propane tank 

before operating this product. Failure to comply with all instructions can result in serious bodily injury, death and/or prop-

erty loss. CARBON MONOXIDE HAZARD - Operating this item in an enclosed space can kill you. Never use this appliance 

indoors or in an enclosed space such as a camper, tent, car, boat or home. Zodi assumes no responsibility for improper use. 

These directions may refer to options not included on your model. Keep children and pets away from product when operating. 

Operate outdoors in well ventilated areas clear of any exhaust or fumes. 

DO NOT OPERATE INDOORS. FOR OUTDOOR USE ONLY!

Air must be flowing through air tubes before igniting and whenever heater is on.

This package contains: 

• X-40 Hot Vent

•12 volt fan with battery clips

• high temp flexible air hoses (2)

• multi-purpose storage bag

• instruction manual

• warranty card

 

STEP 1

Select flat ground, outdoors in well-

ventilated area 15 ft (5 M) clear of vehicles, 

exhaust & flammable materials. Extend all 

4 support legs by depressing button in leg/

bracket and rotate legs downward until 

secure and locked.

STEP 2

Leave propane valve in off position. Check 

that propane valve on X-40 Vent is in 

“OFF” position. Securely connect propane 

regulator to propane tank. Before using 

system, check for leaks (see next page). 

Securely position propane tank in an 

upright position a safe distance away from 

heater. 

STEP 3

Attach both air hoses to collars on each 

side of X-40 Vent by compressing each 

air hose end to form an oval shape. 

Slide air hose completely over X-40 

Vent Collar. Extend air hose so each air 

hose is about 3 to 4 ft. X-40 Vent should 

remain at least 3 ft from tent.

STEP 4

Place free end of air hose inside tent. For 

best performance wrap X-40 Vent air hose 

with a small towel where air hose enters 

tent. Towel will protect zipper & keep cold 

air from entering tent. Position air hose 

away from heat sensitive items & fabrics. 

Keep air hose as straight as possible. 

STEP 6

When ready to turn on heater, connect 

battery clips to battery. Red to positive 

(+) and Black to negative (-) terminal 

on 12-Volt power source. Air will be 

flowing from output air hose. 

AIR MUST ALWAYS BE FLOWING FROM FREE 
END OF OUTPUT AIR HOSE WHEN HEATER IS ON!

STEP 7

AIR MUST BE FLOWING BEFORE 

PROCEEDING. Turn gas on propane 

tank to ON/Open position. On front of 

the X-40 Vent, push in propane valve 

and turn DOWNWARD to the ON 

position while pushing in and holding 

the ignition button for 5 seconds.

STEP 8

System should ignite instantly. Once 

system is ignited, release ignition 

button. Check for ignition by feeling 

for heat rising from the top of the X-40 

Vent. If system fails to ignite, shut off 

propane valve and wait one minute. 

Repeat Step 7.

SHUT DOWN

Turn propane valve on front of X-40 Vent “OFF” then turn “OFF” 

propane tank gas valve. Allow fan to continue blowing air for 2 

minutes before turning “OFF” fan. Turn fan off by removing clips 

from 12 V power source. Allow X-40 Vent to cool completely. 

Remove regulator from propane tank before handling, storing or 

transport.

NOTES:

 

INSULATE TENT - The X-40 Vent is designed to heat 

your tent when outside air temperature is between 30° to 60°. 

Below 30° propane loses performance and the total area of 

the tent walls may disperse hot air away faster than the X-40 

Vent can supply hot air. In cold areas, add an extra layer of 

insulation to your tent, such as securing a blanket or a plastic 

tarp on the outside of  tent. Also, cover any screens in the tent 

roof with towels, etc. Keep heater outside of tent and tarp. Do 

not put tarp above heater.

STEP 9

If the push button fails to ignite 

replace AA battery or insert match 

or lighter flame in manual ignition 

hole on the back side of heater then 

slowly OPEN gas valve.

Tips for Best Performance

If you experience a challenge with your Zodi X-40 Vent Heater 

PLEASE DO NOT return product to the store.

PLEASE Call 800-589-2849 or e-mail [email protected]

CAUTION

STEP 5

Place input air hose with fan away from 

all vehicle exhaust and fumes. Elevate fan 

and output air hose off ground. Also, air 

hose end with fan can be placed inside 

tent to recirculate air. Do not obstruct the 

flow of air near bottom or top of heater. 

Keep clear of rotating fan when fan is on!

WARNING - SYSTEM GETS HOT DURING USE:

 

Allow system to cool 

before handling. Do not place any items on or near heater. Keep children 

& pets clear of heater when operating. Operate only outdoors in well 

ventilated areas clear of any flammable vapors & material and any exhaust 

or fumes. For best performance, shield system from wind and use full 

propane tanks stored at room temperature.

DO NOT USE SYSTEM INDOORS: 

The X-40 Vent, like all propane devic-

es, generate deadly, odorless, carbon monoxide fumes when operating. 

The X-40 Vent is designed for outdoor use only. Do NOT operate the X-40 

Vent inside boats, RVs, tents, homes or other confined areas. Use only 

outdoors in well ventilated areas away from flammable materials, vapors, 

fumes or exhaust. Only the end(s) of the flexible air hose(s) should enter 

the tent.

 Do not operate unattended. X-40 Vent is designed for 

temporary heating only. Do not sleep with X-40 Vent operating.

BEFORE EACH USE: 

 Prior to each use, completely inspect your X-40 

Vent internal heating tubes and heating tube flanged ends for damage. Do 

not use your X-40 Vent if the heating tubes are damaged. 

CONNECTING PROPANE:

 

This product uses propane gas. Propane gas 

can explode, burn and is a fire hazard. Propane gas is heavier than air and 

can accumulate in low areas. Never store propane indoors or near any 

heat source, near any open flames, near any pilot light, in direct sun light, 

near any ignition source or where temperatures exceed 120°F. Dispose 

of empty gas cylinders in a safe and responsible manner. Always attach 

& detach gas cylinder outdoors away from flames, other ignition sources 

& only when heater is cool to touch. If propane cylinder has a protective 

cap, remove protective cap. Check that propane cylinder and fittings are 

clean and free of dirt and debris. Turn off propane gas valve, connect 

X-40 gas regulator to the propane tank until connection is tight. Do NOT 

overtighten. Check for leaks at connection of regulator to tank with soapy 

water (see below). 

TESTING FOR GAS LEAKS:

 

To ensure safety, test for propane leaks 

before using X-40 Vent. Never use flame to check for leaks. With propane 

valve turned completely off and propane connected to X-40 Vent, 

apply soapy water (1 part liquid detergent to 3 parts water) around area 

where the gas valve connects to the propane. Bubbles near propane 

connection indicate leaks. If bubbles are present, ensure the propane 

connection is not crossthreaded. Check that propane cylinder connection 

is tight. Repeat process (test for leaks) until no leaks are present. If leaks 

persist, do not use product, but contact Zodi.

WINDY CONDITIONS: 

The X-40 Vent is designed to be operated in calm 

conditions with wind less than 5 mph. In windy conditions the burner 

flame will be extinguished. If flame is extinguished, immediately turn 

propane burner off. X-40 is NOT intended to be operated during sleeping 

periods.

INPUT TUBE UP-WIND: 

 Always keep the input air hose and fan away 

from vehicle exhaust, generators and other sources of carbon monoxide 

or any fueled exhaust. 

Only the ends of the air hoses

 should enter tent. 

Heater must always be securely positioned outdoors when heating

ADJUST OUTPUT AIR TEMPERATURE:

 Adjust air temperature with gas 

control knob located on front of X-40 Vent near bottom of panel. If air is 

too hot, reduce gas flow using propane valve. If air is not hot enough, 

increase gas flow using propane valve on front of X-40 Vent or recycle air.

RECYCLE AIR: 

To recycle air, place both input and output air hose 

ends inside tent (KEEP X-40 HOT VENT OUTSIDE). Keep output 

air hose away from heat sensitive items and fabrics. Keep clear of 

fan when fan is on. BTU output varies and may reach up to 40,000 

BTU dependent upon altitude, atmospheric conditions, outside 

temperature, and propane level and temperature. Cold and empty 

propane tanks decrease performance. Also, fully charged batteries 

and different 12 Volt power sources may result in higher flows of air, 

causing lower output air temperatures. For best performance, use a 

full propane tank stored at room temperature. High altitude can result 

in lower output air temperatures. Do not use in wind.

FLEXIBLE AIR HOSES: 

The air hoses are flexible for storage and 

convenience. For best performance minimize bends in air hoses 

when heating by keeping air hoses as straight as possible. If longer 

air hoses are needed, always use Zodi supplied air hoses. Heating 

performance will drop with longer air hoses. The output air hose and 

X-40 Vent get very hot when in use and may cause damage to certain 

materials. For best performance, wrap the output air hose with a 

small towel or sock where air hose enters tent. The towel will protect 

the zipper and will also keep cold air from entering the tent around 

air hose. USE CAUTION WHEN REPOSITIONING AIR HOSES OR 

HEATER. Keep heater and air hoses clear of temperature sensitive 

materials including tent floors, sleeping bags or clothing. Zodi is 

not responsible for damage. Air hoses must be completely attached 

to metal sleeves on X-40 Vent whenever heater is operating. After 

prolonged use, the air hose ends may harden and may need trimming 

before next use. Do NOT use plastic or third party air hoses. Flexible 

air hoses should be replaced with each season. See www.zodi.com 

for replacement air hoses. Attach flexible air hoses to heater and turn 

ON fan by connecting to 12 Volt power source. You should NOT be 

able to feel any air blowing from sealed heating area, only from the 

end of the air tube (air will be cold because heater is OFF.) If fan does 

not operate, confirm battery clips are connect to battery properly (red 

to (+) and black to (-) or try new 12 Volt power source.

REMOVING PROPANE FROM UNIT:

 Only attach or detach gas 

cylinder outdoors, away from flames and ignition sources, after 

the heater has cooled completely. To remove propane from your 

shower, untwist propane regulator on X-40 from valve on propane 

tank until fully removed. Replace protective cap on propane tank. 

Store propane outdoors. Read manufacturer’s directions on propane 

cylinder for other warnings. 

CLEANING RECOMMENDATIONS:

 Clean outside of housing and 

flexible air hoses using a soft damp c h and only when completely 

cool. Never submerge heater in water. Check tubes before each use.

STORAGE:

 

Disconnect propane cylinder from heater before and 

during transport or storage. For added protection, wrap heater in 

towel before storing in storage bag. Store heater in storage bag 

to prevent dust and insects from clogging burner during storage. 

Damaged and torn storage bags and fans are not covered by 

warranty. Always store propane outdoors - see propane warnings.

Warranty Disclaimer:

 Due to the harsh conditions product may be 

exposed to, there is no warranty on electronic components including 

electronic ignition and fan. Never modify, alter or use with any part or 

device not approved by Zodi.