10

Danger of death from electric shock!

Solar modules generate electricity as soon as they are exposed to light. One module on its own

is below the safety extra low volt level, but multiple modules connected in series (summing the voltage)

or in parallel (summing the current) represent a danger. The following points must be observed when

handling the solar modules to avoid the risk of fire, sparking and fatal electric shock.

Do not insert electrically conducting parts into the plugs or sockets!

Do not fit solar modules and wiring with wet plugs and sockets!

Exercise utmost caution when carrying out work on wiring and safety equipment (use insulated

tools, insulated gloves, etc.)!

Do not use damaged modules! Do not dismantle modules! Do not mark on the rear of the

module using sharp objects!

Exercise utmost caution when working on wiring and the inverter. Be sure carefully to follow

manufacture’s installation instructions!

Artificially concentrated sunlight shall not be directed on the modules or panels!

11

Danger of death from arcing

Modules generate direct current when light shines on them. An arc may be produced when

connections are separated. We therefore recommend covering modules with a lightproof cloth during

installation. When breaking a connected string of modules (e.g. when disconnecting the DC line from

the inverter under load), a lethally strong arc can occur:

Never disconnect the solar generator from the inverter while the inverter is connected to the

mains grid—remove the fuse from the AC side on the inverter first!

Ensure cable connections in perfect condition (no splitting, soiling or other contamination)!

Remark: all sizes are measured in mm; and tol/- 2 mm

Содержание ZXM6-HD120

Страница 1: ...ntenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personne...

Страница 2: ...Nominal Mass kg 26 5kg 22 5kg 24 5kg 24kg 23kg 22kg 22kg 21 5kg Package Size mm 2000 992 25 27 30 35 2024 1002 25 27 30 35 2020 1002 25 27 30 35 2040 1002 25 27 30 35 1844 992 25 27 30 35 1860 1002 25...

Страница 3: ...r fountain Antisepsis keep away from salt erode and sulfuration places Do not wear rings jewelry watches or other metallic items while working with photovoltaic modules 3 Mounting and notes The module...

Страница 4: ...be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will be satisfactory during the rest of the year The module tilt angle is measured between t...

Страница 5: ...t and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influe...

Страница 6: ...ules are strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used must not come into contact with the front glass and mu...

Страница 7: ...m compression for each clamp is 20MPa 2900PSI The module mounting structure must be made of durable corrosion resistant and UV resistant material All mounting hardware bolt flat washer split washer nu...

Страница 8: ...le material Use cable extensions and plugs that are designed for outdoor application Ensure that they are in perfect electrical and mechanical condition Use only cables having one conductor Select the...

Страница 9: ...k on the rear of the module using sharp objects Exercise utmost caution when working on wiring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concent...

Страница 10: ...ass 5 as mono panels doped with gallium non coated glass 7 as mono panels doped with boron coated glass 8 as poly panels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8...

Страница 11: ...400 405 Max Power Voltage Vmp V 40 6 40 8 41 41 2 Max Power Current Imp A 9 61 9 69 9 76 9 84 Open Circuit Voltage Voc V 48 7 48 9 49 1 49 3 Short Circuit Current Isc A 10 08 10 21 10 27 10 33 Module...

Страница 12: ...STC Model Type ZXM6 HLD120 315 M ZXM6 HLD120 330 M Max Power Pm W 315 330 Max Power Voltage Vmp V 33 3 33 9 Max Power Current Imp A 9 47 9 74 Open Circuit Voltage Voc V 40 40 6 Short Circuit Current I...

Страница 13: ...oltage VDC 1500 A Max Series Fuse A 15 Electrical Performance STC Model Type ZXP6 HLD132 315 P ZXP6 HLD132 330 P Max Power Pm W 315 330 Max Power Voltage Vmp V 35 1 35 7 Max Power Current Imp A 8 98 9...

Страница 14: ...r Voltage Vmp V 32 5 Max Power Current Imp A 9 24 Open Circuit Voltage Voc V 39 5 Short Circuit Current Isc A 9 58 Website www znshine com Address 1 Zhixi Industry Zone 213251 Jintan Jiangsu PEOPLE S...

Отзывы: