ZMC306X Motion Controller User Manual V1.5
→
Terminal Definition
Terminal
Name
Type
Function 1
Function 2
EGND
/
E5V power ground /
IO public end
/
E5V
/
5V power output,
max is 300mA
/
OUT0 NPN Leakage type,
high-speed output
Output 0
PWM 0
OUT1
Output 1
PWM 1
OUT2
NPN Leakage type,
low-speed output
Output 2
/
OUT3
Output 3
/
OUT4
Output 4
/
OUT5
Output 5
/
OUT6
Output 6
/
OUT7
Output 7
/
EGND
/
IO public end
/
OUT8
NPN Leakage type,
low-speed output
Output 8
/
OUT9
Output 9
/
OUT10
Output 10
/
OUT11
Output 11
/
Note:
The E5V power output port is used for PWM or common anode wiring of single-
ended axis. It is not recommended for other purposes due to lower power.
OUT0-1 have the function of PWM. When PWM is off, it is general output.
3.5.1.
Digital Output Specification & Wiring
→
Specification
Item
High Speed Output (OUT0-1) Low Speed Output (OUT2-11)
Output mode
NPN leakage type, it is 0V when outputs
Frequency
<
400kHz
<
8kHz
Voltage level
DC24V
DC24V
Max output current
+300mA
+300mA
Max leakage
25μA
25μA