XPLC300 Motion Controller Hardware Manual V1.5
The default starting address of IO, AD and DA with ZMIO extension is 32, and the
addresses of modules of the same type continue automatically. If you need to offset the
starting address, please refer to the content of the configuration function below.
Type
Relative instructions
Relative view
Examples
Input
IN
Input view
IN (32) ~ IN (79)
Output
OP
Output view
OP (32) ~ OP (63)
AD
AIN
AD/DA view
AIN (32) ~ AIN (35)
DA
AOUT
AD/DA view
AOUT (32) ~ AOUT (35)
The AD and DA with ZMIO extension use the standard range (0~10V) by default. If you need
other ranges, please contact the manufacturer to replace them in advance.
4.2.
Function Configuration
Configuration includes local offset configuration and built-in ZMIO expansion
configuration, which can be further divided into IO configuration and analog configuration.
4.2.1.
Local IO Offset Configuration
Functional Description
It is used to offset local IO address of XPLC300 controllers.
Grammar
LOCALIO_OFFSET=value
Parameter List
value
IO starting address
Default: multiples of 0 and 8
Example
LOCALIO_ADDRESS=8
‘
local IO address is offset to 8
Note: IO starting address only can be set as the multiple of 8.
Controller status (before modification):
Controller status (after modification):
Содержание XPLC300
Страница 1: ......