ECI3828 Network Motion Control Card User Manual V1.5
3.3.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use any ETHERNET or RS232 (there is default parameter,
which can be connected directly) to connect to ZDevelop.
(3)
Please use the "ADDRESS" and "SETCOM" commands to set and view the protocol
station number and configured parameters, see "ZBasic Programming Manual" for
details.
(4)
According to their respectively instructions, correctly set the relevant parameters of
the third-party equipment to match the parameters of each node.
(5)
When all is configured, it can start to do communicating.
(6)
Communication data of RS232 can be directly viewed through “ZDevelop / Controller
/ State the Controller / CommunicationInfo”.
3.4.
IN Digital Input & High-Speed Latch Port
The digital input adopts 3 groups of 10Pin screw-type pluggable terminals, and the
gap distance between terminals should be 5.08mm. In addition, the high-speed latch
Содержание ECI3828
Страница 1: ......