ECI0016PA Data Capture Card User Manual V1.5
3.2.
IN: Digital Input
The digital input adopts one 10Pin screw-type pluggable terminals, and the gap distance
between terminals should be 3.81mm.
→
Wiring Definition
Terminal
Name
Type
Function 1
IOGND
/
IO Power Ground
IOGND
/
IN0
NPN leakage type,
low-speed input
Input 0
IN1
Input 1
IN2
Input 2
IN3
Input 3
IN4
Input 4
IN5
Input 5
IN6
Input 6
IN7
Input 7
3.2.1.
Digital Input Specification & Wiring
→
Specification
Item
Low-Speed Input (IN0-7)
Input mode
NPN leakage type, the input is triggered when
there is low-electric level
Frequency
<
5kHz
Impedance
4.7K
Ω
Voltage level
DC24V
The voltage to open
<14.5V
The voltage to close
>14.7V
Minimal current
-1.8mA (negative)
Maximum current
-6mA (negative)
Isolation mode
optoelectronic isolation
Note: the above parameters are standard values when the voltage of control card
power supply (E+24V port) is 24V.