Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com
12
6
DCR
Input
Same as CTS
7
RTS
Output
After the flow control in using, the serial device server
will accept the data of the serial device when the pin is 0.
8
CTS
After the flow control in using, the serial device server
will send the data to the serial device when the pin is 0.
5.
Reset switch:
also known as DEF switch, as shown in figure 5. When the
DEF switch is On (the right side of figure 5 is On), the serial device server will
start loading the default parameters, and when pressed to On state for 5
seconds, the default parameters will be used to restart. The default
parameters only affect the following parameters: IP mode to static, IP address
to 192.168.1.254, subnet mask to 255.255.255.0, gateway to 192.168.1.1.
Other parameters such as baud rate will not be reset. If all parameters need to
be reset, please use the "system default parameter" of ZLVircom configuration
tool for modification. The DEF switch is mainly used to make it easy to enter
192.168.1.254 in the browser to reconfigure the device when the IP is
forgotten. The Protect switch is for future use.
6.
Indicator light:
it is divided into Power, Link and Active lamps, which
respectively represent Power supply, connection indicator and data indicator.
Table 3 Meaning of Indicator Light
Power
Indicator
Instruction
Link
Indicator
1) Link lamp is green when the network line is connected.
2) When the TCP connection is established (or in UDP mode),
the Link is blue (actually with faint green light). Can be used
to determine whether the serial device server establish a
communication link with the upper computer.