ZK-D4330 (TP Version)                                                          User Manual 

Copyright©2021 ZKTECO CO., LTD. All rights reserved.

 

P a g e

  |

  32 

It is used to set the ringtone when the alarm rings, a total of 16 ringtones can be selected. 

Operation:

  Press the 

[OK]

  button to enter the ring tone setting  interface, then press the

 

[▲]

/

 

[▼]

 

button to select, press 

[OK]

 button to save and exit.

 

 

Alarm Mode 

NOTE: 

When the 

Zone 

is selected as "

06 Independent Zones

", the 

Alarm Mode 

function can 

be set in the alarm setting interface.   

Select 

Alarm Mode

 on the Alarm setting interface, and press the 

OK

 to enter the alarm mode 

setting interface, as shown in the following: 

 

Function Description 

Menu 

Descriptions

 

All Zone 

In the All Zone alarm mode, when the detected metal content reaches 
or exceeds the set metal content, the area alarm light of the detected 
metal will be serial lit, and an alarm will sound at the same time. Suitable 
for normal mode. 

Interval Zone 

In the Interval Zone alarm mode, the zone warning lights that detect 
strong metal content will light up at intervals, that is, two consecutive 
zones will not light up at the same time. Facilitates identification and 
focused detection of stronger zones by security personnel. 

Single Zone 

In the Single Zone alarm mode, only the zone with the strongest metal 
content is detected and the alarm lamp lights up. Facilitate the security 
personnel to precisely focus on the area for detection. 

 

Содержание ZK-D4330

Страница 1: ...ersion 1 0 English Thank you for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images sh...

Страница 2: ...operating and maintenance personnel are fully familiar with the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is furthe...

Страница 3: ...dments are meant for improvement better operations of the machine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall...

Страница 4: ...nd development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the c...

Страница 5: ...NSTALLATION 9 3 1 SAFETY PRECAUTIONS 9 3 2 INSTRUCTIONS FOR THE PEDESTRIANS 9 3 3 INSTALLATION SETUP REQUIREMENTS 10 3 3 1 METALLIC ITEMS 10 3 3 2 FLOOR 10 3 3 3 ELECTROMAGNETIC RADIATION AND INTERFER...

Страница 6: ...INTERFACE 22 8 2 MAIN MENU 23 8 3 SENSITIVITY ADJUSTMENT 25 8 4 ZONE MODE 26 8 5 CHANNEL SETTINGS 28 8 6 ALARM SETTINGS 30 8 7 AUTO TESTING 33 8 8 SECURITY LEVEL 36 8 9 SCENARIO 36 8 10 LOG QUERY 37...

Страница 7: ...ing metal object s larger than the preset size the device will immediately generate alarms and display the alarm location as well The people detected with metal need to be checked by the security guar...

Страница 8: ...D All rights reserved P a g e 7 1 3 Components 1 Transparent Rainproof Canopy Optional 2 Front Beam 3 Rear Beam 4 Host 5 Alarm Indicator Post 6 Infrared Sensors 7 Waterproof Foot Cover 8 Power Interfa...

Страница 9: ...2 Product Specifications 2 1 Dimensions Front View Side View 2 2 Technical Specifications Feature Specifications Power DC 15V 5A Operating Temperature 20 C to 50 C Dimensions External 2220 H x 930 W x...

Страница 10: ...as it may cause false alarms Do not disassemble the unit without the guidance of a professional technician Each device has a warranty card with which users can have their devices maintained or repair...

Страница 11: ...the detector uses Bilateral Receiver technology it must be installed at a distance of at least 1 m away from the sources of electromagnetic radiation or electromagnetic interference as it may affect...

Страница 12: ...ions After reading the precautions and checking the packing list please follow the steps below for installation Step 1 Open the package and then place the left and right door panels on the ground in t...

Страница 13: ...ZK D4330 TP Version User Manual Copyright 2021 ZKTECO CO LTD All rights reserved P a g e 12 Figure 3 2 Step 3 Open the beam cover as shown in the figure3 3 below Figure 3 3...

Страница 14: ...ECO CO LTD All rights reserved P a g e 13 The disassembly skills are shown in the figure 3 4 below Figure 3 4 Step 4 Connect the front beam with the left and right door panels with bolts and tighten 8...

Страница 15: ...all the adjustable metal bracket on the host The screws and holes on both sides of the bracket can fix and adjust the display angle of the host as shown in the figure 3 6 below Figure 3 6 Step 6 Pass...

Страница 16: ...host and the front cross beam with bolts as shown in the figure 3 8 below if the rain cover is optional it can be installed together Figure 3 8 Step 8 Insert and tighten the left and right signal wire...

Страница 17: ...n User Manual Copyright 2021 ZKTECO CO LTD All rights reserved P a g e 16 Step 9 Cover the beam cover as shown in the figure 3 10 below Figure 3 10 The installation skills are shown in the figure 3 11...

Страница 18: ...ZKTECO CO LTD All rights reserved P a g e 17 Step 10 Lift and move the security gate to the designated working position connect the side power cord and press the power switch to enter the working stat...

Страница 19: ...ity level of a detection zone the LED light mapping of the detection zone turns on Digital Pulse Technology Digital signal processing and filtering system in the detector has excellent anti interferen...

Страница 20: ...alarms detection signal strength time and channel etc 2 Return Button Exits the current menu item 3 Up Button Selects a menu item or increases a value 4 Down Button Selects a menu item or decreases a...

Страница 21: ...tons of the Remote Control and their description are given below 1 RESET Undefined 2 PROG Long press 3 seconds to turn off the device 3 ESC Exits the current menu item 4 UP LEFT Selects a menu item or...

Страница 22: ...being connected to a power supply the metal detector starts to work When no person or object passing through the device the infrared sensors stop alarming to avoid false alarm and accurately count pas...

Страница 23: ...through Note If you want to decrease the sensitivity in a certain zone you must only adjust the sensitivity of the related zone After implementing the above adjustments the metal smaller than the samp...

Страница 24: ...eted as shown in the following figure NOTE There are two ways to operate this device the first is to click on the touch screen for operation such as directly clicking on the screen icon to select the...

Страница 25: ...etting and Auto Setting Alarm Used for alarm settings including parameters such as Volume Delay Ring Tone Random Alarm and Alarm Mode Auto Testing Automatically detect whether the functions of each mo...

Страница 26: ...in the following Global Sensitivity Select Global Sensitivity on the Sensitivity interface and press OK to get into its setting interface as shown in the following The larger the global sensitivity th...

Страница 27: ...efault value is 475 Note You need to set up independent defense zones in the Defense Zone Settings interface first Operation Press the OK button to enter the sensitivity setting interface then press t...

Страница 28: ...CO CO LTD All rights reserved P a g e 27 Operation Press the OK button to enter the zone setting interface then press the button to select press OK button to save and exit Remark Different independent...

Страница 29: ...ons only click this partition again or press OK to confirm and the icon will disappear 8 5 Channel Settings Select Channel on the Main Menu interface and press OK to enter the band setting interface a...

Страница 30: ...er finishing directly press button to exit to the upper menu without saving the current value Auto Setting Select Auto Setting on the Channel interface and press OK to get into its setting interface a...

Страница 31: ...and press OK to enter the alarm volume settings interface as shown in the following Used to set the alarm volume the larger the value the higher the volume valid values are 0 to 100 the default value...

Страница 32: ...he effective value is 1 to 99 seconds the default value is 1 second Operation Press the OK button to enter the setting interface then press the button to increase or decrease the value press OK button...

Страница 33: ...ollowing Function Description Menu Descriptions All Zone In the All Zone alarm mode when the detected metal content reaches or exceeds the set metal content the area alarm light of the detected metal...

Страница 34: ...ty threshold while it can pass normally when it is less than the threshold When a random alarm value is set there will be a n probability that a normal pass without alarm will be turned into an alarm...

Страница 35: ...Alarm setting interface and press OK to enter the partition test The test example is shown below Operation Press the OK button to enter the partition test then press button to exit to the upper menu L...

Страница 36: ...and when Light Up the Red Light is selected the red light of the light bar around the door panel will light up immediately It means that this function is normal press the button to exit to the upper...

Страница 37: ...ing sensitivity Operation Press the OK button to enter the security level setting interface then press the button to select press OK button to save and exit 8 9 Scenario Select Scenario on the Main Me...

Страница 38: ...Operation Click the custom scene icon in the upper right corner of the screenor press the power button to enter the setting interface Click on the screen to select a custom scene click on the zone to...

Страница 39: ...d confirm the query On the query result page when there are many records you can press the button or click the button on the screen to turn the page to view Press the button to exit the record query 8...

Страница 40: ...ss OK button to save and exit Screen Sleep Select Screen Sleep on the System setting interface and press OK to enter the screen hibernation setting interface as shown in the following You can set the...

Страница 41: ...ton to select Press OK button to set the value select Confirm and press the OK button to save and exit Language Select Language on the System setting interface and press OK to enter the language setti...

Страница 42: ...owing It is used to set whether to save the number of alarm records after the device is turned off select Yes to save and select No to clear Operation Press the OK buttonto enter the settinginterface...

Страница 43: ...nterface and press OK to enter the detect mode setting interface as shown in the following Function Description Menu Descriptions Automatic Detection Mode In this mode an alarm is generated when the a...

Страница 44: ...utput a switch signal when the machine does not alarm Abnormal open In this mode when the metal content exceeds the alarm threshold the machine will trigger the relay to output a switch signal when th...

Страница 45: ...ress the button to select setting item Press the OK button to set the value of 0 to 9 select confirm and press the OK button to save and exit 8 12 Default Parameters Parameter Default Value Default pa...

Страница 46: ...els b Check whether there is any infrared interference beside the device such as infrared surveillance system infrared remote control outdoor sunlight etc c If both condition a and condition b are OK...

Страница 47: ...ity 1 L Side Panel 1 set 2 R Side Panel 1 set 3 Front Beam 1 pc 4 Rear Beam 1 pc 5 Accessory Box 1 pc 6 Universal Wheel Optional 4 pcs 7 Transparent Rainproof Canopy Optional 1 pc Accessory Box List N...

Страница 48: ...ignated dealer 3 This card will be regarded as invalid if the details are not filled in guarantees column and the acknowledgment of the receipt Please confirm whether the data filled in the guarantees...

Страница 49: ...ZK D4330 TP Version User Manual Copyright 2021 ZKTECO CO LTD All rights reserved P a g e 48 Date of Maintenance Record of Maintenance Technician...

Страница 50: ...Copyright 2021 ZKTECO CO LTD All rights reserved ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com...

Отзывы: