22 ZK-D1065S User Manual

Date of Maintenance

Record of Maintenance

Maintainer

Содержание ZK-D1065S

Страница 1: ...Contents 1 User Manual Walk Through Metal Detector ZK D1065S Version 1 2 Date December 2019...

Страница 2: ...on 2 Installation Environment 3 Performance and Features 5 Application 7 Parts 8 Installation 9 Control Panel 11 Detection Zones 12 Operation 13 Detection Adjustment 16 Brief Maintenance 18 Technical...

Страница 3: ...ouch the detector during security checking to avoid false alarm 3 Make sure there s no big metal object or strong magnetic field around the detector within 2 meters 4 Detector probe mustn t install in...

Страница 4: ...to check the metal items hidden on the body When the passengers pass through the device if they carried metals more than preset parameters value the device would immediately alarms and display alarm l...

Страница 5: ...device about 2 meters to avoid false alarm 3 Floor Vibration The floor should be flat and fixed to avoid false alarm after installation by the movement of people walking or moving and shaking of metal...

Страница 6: ...rmer Ac Power Lines Thyristor Control Circuit High Power Switching Power Supply Inverter Welder Engine Motor etc 5 Side By Side Using When installing the devices side by side the distance between two...

Страница 7: ...detection zone has 100 sensitivity levels 0 99 Preset metal size you can exclude the coins keys jewelry belt buckle etc Digital Pulse Technology digital signal processing and filtering system has exc...

Страница 8: ...ot only can fixed the device but also waterproof Waterproof using PVC synthetic material special technology waterproof fireproof shockproof Easy to install the system is integrated design just 15 minu...

Страница 9: ...ll exhibition business event celebration stadium and other important public places 4 Important industrial and mining enterprises such as hardware electronics jewelry mint to prevent the loss of precio...

Страница 10: ...8 ZK D1065S User Manual Parts 1 Control Unit Case 2 Alarm zone LED 3 Built in Probe 4 Infrared Sensors 5 Waterproof Foot Cover 6 Power Line Interface 1 2 4 5 3 6...

Страница 11: ...nit and door panel 2 Put the control unit case and door panels as above picture shown and then connect the left and right door panel with the control unit case by bolts Tightening screws 3 Probe line...

Страница 12: ...10 ZK D1065S User Manual 4 Lift the walk through metal detector to the vertical position and move to the assigned position 5 Plug power cable...

Страница 13: ...the tens digit when setting the zone sensitivity level If press SETUP for 5 seconds you can adjust the frequency From frequency 1 to frequency 12 is optional 3 SELECT choose each program and increase...

Страница 14: ...eans whole sensitivity and the sensitivity levels higher the sensitivity higher If the metal reaches or exceeds preset value the red LED alarm If there are multiple alarm targets the LED light of each...

Страница 15: ...ECT to select zone 2 7 to adjust corresponding zone sensitivity especially zone 7 is whole sensitivity xx is sensitivity level press SETUP to adjust tens digit press ENTER to adjust unit digit the big...

Страница 16: ...ark xx means working frequency press SETUP to select frequency the scope for working frequency is 1 12 can be selected Startup Shutdown Press RESET five seconds to startup or shutdown Password input F...

Страница 17: ...ELECT Input password Display Press SETUP to shift ENTER ENTER Change password Remark If you forgot the password you can input the universal password 88888 to reset a new password 00000 0 000 Increase...

Страница 18: ...buckle shoes and so on according to the following steps to adjust a Choose a small metal as the sample such as keys b Increasing the sensitivity so that when the tester carry the sample and pass throu...

Страница 19: ...rried metal objects such as keys mobile phone watch coins etc place on the side of security chute or a table and pick it up after security checking c Passengers should line up one by one to pass the d...

Страница 20: ...e OK please replace the Infrared sensor 2 False alarm a After installation if the device gives false alarms frequently firstly check the installation environment Make sure there is no movable or stati...

Страница 21: ...ltage 100 240V 50 60Hz Power 12W Gross weight 70KG Working temperature 20 50 Sensitivity 100 steps adjustable Alarm Visible and audible alarm Inner Dimensions 1990mm High x 700mm Wide x 578mm Deep Ext...

Страница 22: ...Packing List Package should contain the following items 1 L side panel 1set 2 R side panel 1set 3 Control Unit 1pc 4 User manual 1pc 5 Power cord 1pc 6 Threaded bolt 8pcs 7 Hexagon wrench 1pcs 8 Prob...

Страница 23: ...d will be regarded as invalid if it has not been filled in details three guarantees and acknowledgment of receipt Please confirm whether the data filled in the three guarantees and acknowledgement of...

Страница 24: ...22 ZK D1065S User Manual Date of Maintenance Record of Maintenance Maintainer...

Страница 25: ...ZK D1065S User Manual 1 Copyright 2019 ZKTECO CO LTD All rights reserved ZKTeco Dongguan Industrial Park No 26 Pingshan 188 Tangxia Dongguan China Tel 86 769 8210991 8210992 8210993 www zkteco com...