TS5000A Quick Start Guide 3
3.
If DIPs “1” and “2” are “ON” and DIPs “3” and “4” are “OFF”, the device will be tested automatically.
3.3 Button board settings
Cut off the power, connect the port of button board to RS232 port of the control panel. Power the device up after
connection.
K1 (select), K2 (+), K3 (-)
A: Open mode
1: Set as “A---0” (card swiping on both left and right); indicators are as shown below:
2: Set as “A---1” (card swiping on the right; free on the left); indicators are as shown below:
3: Set as “A---2” (card swiping on the left; free on the right); indicators are as shown below:
4: Set as “A---3” (free on both left and right); indicators are as shown below:
B: Open duration time (S)
F: Brake angle
Note:
After completion of settings, please press and hold the K1 button for 3 seconds. When the indicator is shown