long beep.  

After that the system returns to verification state, the Green LED blinks once every two seconds (the buzzer 

has no beep).  

Note

You have to reboot device again to register management card if it’s operation timeout

You can 

use the Software to configure or modify the management card once it is registered. 

Operation Timeout: 

When there is no operation after 15 seconds, the device will automatically return to 

verification state.  

Verification State: 

It is a state that for users to verify their identity and unlock the door. The Green LED 

blinks once every two seconds (the buzzer has no beep).

 

 

You can add or delete users by swiping a management card for different times in a row: 
• 

By swiping the management card once, the system enters to 

single user enrollment state

• 

By swiping the management card five times in a row, the system enters to 

single user deletion state

Note:

 the interval between each two swipes in a row should be less than

 5 seconds

 

 

12. Enrolling an Ordinary User 

To enroll an ordinary user by management card, the system will automatically generate an ID number to the 

user and it enters to enrollment state.

  

Enrollment state:

 It is a state to enroll single users. The green LED blinks twice every three seconds, at the 

same time the buzzer has two short beeps every three seconds. 

Note

:

 It is allowed to enroll one user only each time

Each user is allowed to enroll one ID card only 

and 10 fingerprints at most

 

To enroll a user, proceed as follows: 

• 

Swipe the management card once, The green LED blinks twice every three seconds, at the same time 

the buzzer has two short beeps every three seconds, thus you can start user enrollment.  

• 

Press the same finger over the sensor three times or swipe a new ID card to the proximity area, if 

enrollment succeeds, the Green LED is normally on for one second, the buzzer has one long beep; If it 

fails, the Red LED is normally on for one second, the buzzer has one long beep. (Generally it is denied 

if the card or the finger has already been enrolled or each press of fingers are not qualified enough, 

please pay attention to place the finger in a right way)

 

• 

The system returns to enrollment state and waiting to swipe the card or press new finger (three times) 

to continue enrollment for the same user.  

• 

Swipe the management card once again to quit enrollment state, the system returns to verification state.  

Please do the same to enroll new users by following above steps. 

Note

: If there is no operation for 20 seconds in enrollment state or enrollment of 10 fingerprints and one ID 

card for the same user completed, the system automatically returns to verification state. Otherwise you have 

to swipe management card once to quit enrollment state. 

Содержание TF1600 ZKTeco

Страница 1: ...t place the Access Control Terminal under strong light Use regulated DC 12V 3A power source supplied from control panel or separately purchased power supply Do not place the Access Control Terminal in...

Страница 2: ...tional Accessories 2 5 Product Introduction 3 5 1 Front View 3 5 2 Rear View 3 6 Installation Diagram 4 7 Product Dimensions 4 8 Cable Specification 5 9 Mounting the Unit 6 10 Hardware Setup 6 11 Mana...

Страница 3: ...control features Anti passback Access control interface for 3rd party electric lock door sensor exit button alarm Slim and elegant design One of the world s smallest fingerprint terminals Sleek and s...

Страница 4: ...Exit Button Alarm Power Supply Controller Electric Bolt Electric Magnetic Lock Mifare Card 12V3A Power Adaptor Metallic Mounting Plate Wall Mounting Screws Holders Software CD Installation Guide Moun...

Страница 5: ...Access Control Terminal Quick Start Guide 3 5 Product Introduction 5 1 Front View 5 2 Rear View...

Страница 6: ...Access Control Terminal Quick Start Guide 4 6 Installation Diagram 7 Product Dimensions...

Страница 7: ...Access Control Terminal Quick Start Guide 5 8 Cable Specification...

Страница 8: ...by a Management Card The device users are classified into administrators and ordinary users Administrators An administrator is allowed to perform all operations including user enrollment deletion del...

Страница 9: ...econds at the same time the buzzer has two short beeps every three seconds Note It is allowed to enroll one user only each time Each user is allowed to enroll one ID card only and 10 fingerprints at m...

Страница 10: ...management card once to quit deletion state the system will return to verification state Please do the same to delete other users by following above steps Note Once the registered card or one of the e...

Отзывы: