background image

Detection Management Settings

Click

 

on

       

System

Detection Management

 

enter the setting interface

 > [

] > [

] to 

13

 

When the 

Allow unregistered people to access

 

is enabled, optionally, set 

Enable 

capture of unregistered person

 to save the temperature data. 

You  can  set  the  value  of 

High  temperature  alarm  threshold

,  and  enable  the 

Temperature over the range; access denied

 and the 

Trigger external alarm

, the 

device  will  send  an  alarm  prompt  when  the  temperature  of  the  user  detected 
exceeds this value, meanwhile the user will be forbidden to access, as shown in the 
following figure. The method of enabling 

Mask detection

 is the same.

Temp. Unit                                                             

Temperature measurement distance                    Far

Detection Management

Display Body Temperature

Enable mask detection

Deny access without mask

Allow unregistered people to access

Enable capture of unregistered person

Trigger external alarm

Clear external alarm

Exter alarm delay(s)                                             255 

Firmware update

Display Thermodynamics Figure

Main Menu

User Mgt.

User Role

COMM.

System

Data Mgt.

Personalize

Attendance 

Search

Autotest

System Info

Access Control

L

Date Time

Access Logs Setting

Face

Fingerprint

Palm Parameter

Reset

Detection Management

System

37.30

0.00

Enable temperature screening with infrared

High temperature alarm threshold

Temperature over the range; access denied

Temperature deviation correction

Temp. Unit

Temperature measurement distance

Display Thermodynamics Figure

Display Body Temperature

Enable mask detection

Deny access without mask

Allow unregistered people to access

Enable capture of unregistered person

Detection Management

Far

O

C

O

C

08:50

Successfully verified.

Name:Mike
User ID:4835
Verify:Face

Normal temperature

O

Temp.: 

36.6 C

Mask Detected

08:50

Failed to verify.

Verify:Face
User ID:4835

Without mask

High body temperature

O

Temp.: 

38.6 C

Содержание SpeedFace-V5L

Страница 1: ...Start Guide Version 1 0 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual SpeedFace V5...

Страница 2: ...h Microphone Fingerprint Sensor RS232 RS485 485B 485A GND TXD RXD GND TXD2 RXD2 RS232 GND 12V 12V GND IWD0 IWD1 WD0 WD1 TX RX TX RX AUX AL AL NC1 COM NO1 BUT GND SEN GND Lock Alarm Exit Button Sensor...

Страница 3: ...CE OF 30 50 cm KEEP SPACES BETWEEN YOUR FINGERS DO NOT KEEP YOUR FINGERS CLOSE DO NOT KEEP PALM OUTSIDE COLLECTION AREA DO NOT KEEP YOUR FINGERS FOLD CURLED Installation Environment INSTALL INDOORS ON...

Страница 4: ...r Avoid wind Avoid direct sunlight 16 C to 35 C 60 8 F to 95 F 30 to 120cm 0 98ft to 3 94ft 0 3 C 0 54 F The recommended operating temperature is 25 C 77 F The recommended distance is 80cm 2 62ft This...

Страница 5: ...Lock Exit button Door sensor Card reader 1 2 3 1 5m Attach the mounting template sticker to the wall and drill holes according to the mountingpaper Fixthebackplateonthewallusingwallmountingscrews Atta...

Страница 6: ...input the IP address and click OK Note In LAN IP addresses of the server PC and the device must be in the same network segment when connecting to ZKBioAccess MTD software 8 7 6 RJ 45 5 4 3 2 1 IP add...

Страница 7: ...with the lock or can be used separately for the lock as shown in the example with NC Lock below 1 Device not sharing power with the lock 2 Device sharing power with the lock Normally Closed Lock FR10...

Страница 8: ...ccess controller 12V IWD1 IWD0 GND WD1 WD0 Wiegand card reader connects to the top 4 pins of the wiegand terminal and the last twopinsareusedbytheAccesscontroller asshowninthefollowingfigure Itsendsth...

Страница 9: ...ster a new user The options include User Mgt New User enteringtheuserIDandName settingUserRole registeringPalm Fingerprint Face Password Badge optional andaddingUserPhoto Main Menu User Mgt User Role...

Страница 10: ...riateserveraddressandportissetonthedevice the searched devices are displayed automatically Search Device Search No device found Download Search Tools to Local Disk Device Type Serial Number Total Prog...

Страница 11: ...emporary Personnel Setting Enable Temporary Personnel Auto audit Self service Registration QR Code URL Yes No Yes No Bits Binary Decimal Hexadecimal Yes No http Server address Port Download QR code im...

Страница 12: ...rofthestandbyinterface Note While pairing the device with ZKBioAccess MTD software Make sure that the option EnableDomainNameisdisabledandthecorrectserveraddressandportareentered Serveraddress Setasth...

Страница 13: ...s Combined Veri cation Anti passback Setup Duress Options Access Control Password Face Palm 1 Gate Control Mode Veri cation Mode Door available time period Normal open time period Master Device Auxili...

Страница 14: ...capture of unregistered person Trigger external alarm Clear external alarm Exter alarm delay s 255 Firmware update Display Thermodynamics Figure Main Menu User Mgt User Role COMM System Data Mgt Perso...

Страница 15: ...f mask thesizeofthefacecoveredbythemask andbangswillaffectthefacialrecog nitioneffect Recommended for indoor use Facial verification for masked individuals will increase FAR Palm verification for mask...

Страница 16: ...None None Name Department Temperature Mask Time UnregisterUser NULL 36 57 Yes 15 01 39 Name Department Temperature Mask Time UnregisterUser NULL 36 57 Yes 15 01 39 Name Department Temperature Mask Tim...

Страница 17: ...ZKTeco Industrial Park No 26 188 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2020 ZKTECO CO LTD All Rights Reserved...

Отзывы: