SpeedFace-V5L-RFID
User Manual
P a g e
| 70
Copyright©2020 ZKTECO CO., LTD. All rights reserved.
out again; otherwise, the alarm will be triggered. However, the user can check in
freely.
In Anti-passback
After a user checks in, only if the last record is a check-out record can the user check
in again; otherwise, the alarm will be triggered. However, the user can check out
freely.
In/Out Anti-
passsback
After a user checks in/out, only if the last record is a check-out record can the user
check in again, or a check-in record can the user check out again; otherwise, the
alarm will be triggered.
10.6
Duress Options Settings
If a user activated the duress verification function with specific authentication method(s), when he/she is under
coercion during authentication with such method, the device will unlock the door as usual, but at the same
time a signal will be sent to trigger the alarm.
Click
Duress Options
on the Access Control interface.
Item
Description
Alarm on
Password
When a user uses the password verification method, an alarm signal will be
generated, otherwise there will be no alarm signal.
Alarm Delay (s)
Alarm signal will not be transmitted until the alarm delay time is elapsed. The
value ranges from 1 to 999 seconds.
Duress Password
Set the 6-digit duress password. When the user enters this duress password for
verification, an alarm signal will be generated.