SBTL9000 Series
User Manual
P a g e
| 8
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
Mechanical System
1.2
The mechanical system of the Swing Barrier turnstile includes the chassis and the core component.
The chassis is a carrier where the Direction indicator, Reader, Infrared sensor, and the Door lock are
installed. The core component mainly consists of the Motor, Frame, Bearing, and Swing Arm.
Electronic Control System
1.3
The electronic control system of a swing barrier turnstile is mainly composed of the Reader, Master
Control Panel, Infrared Sensor, Direction Indicator and Alarm.
Reader:
The reader reads the data in the card and sends it to the Access Controller.
Master Control Panel:
The Master Control panel is the system’s control center that receives
signals from the reader and the photoelectric switch performs logical calculation and processing of
these signals and sends executive commands to the Direction indicator, electric motor and the
alarm.
Infrared Sensor:
It detects the position of the pedestrian and plays the role of safety protection.
Direction Indicator:
This indicator displays the pedestrian passage path and directs them to pass
through the lane in a safe and orderly manner.
Alarm:
The alarm gives an alarm voice if the system detects any unauthorized entry to the passage.
Working Principle
1.4
1.
After supplying power to the device, the system performs Power-On Self-Test. The device
starts normally if no failure is detected. If a failure is detected, the system displays related
messages on the LCD display screen so that the user can have a quick knowledge of the
technical issue and solve the problem.
2.
When the reader detects a valid card/fingerprint, the buzzer will give a positive audible
prompt to the pedestrian, indicating that the card is being read successfully or “fingerprint
successfully verified”. And then, the reader sends signals to the access controller to request
permission to pass through the passage. The access controller will send the signal to the
master control panel.
3.
After receiving the signal from the access controller, the master control panel sends valid
control signals to the direction indicator and the electric motor. At last the direction arrow
turns green.
4.
Pedestrians passes through the passage according to the direction indicator signs. Infrared
sensors keep on detecting the pedestrian during the whole process, and continue to send