background image

SBTL9000 Series

 

 

User Manual 

P a g e

 | 1 

 

Copyright©2020 ZKTECO CO., LTD.  All rights reserved. 

Thank you for choosing our product. Please read the instructions carefully 
before operation. Follow these instructions to ensure  that the product is 
functioning properly. The images shown in this manual are for illustrative 
purposes only. 

For further details, please visit our Company’s website 

www.zkteco.com

 

User Manual 

SBTL9000 Series 

Date:  September 2021 

Doc Version: 1.0 

English 

Содержание SBTL9000 Series

Страница 1: ...d the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For furthe...

Страница 2: ...h the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equi...

Страница 3: ...hine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible I in case the machine unit equipment...

Страница 4: ...ent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fie...

Страница 5: ...scription Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus ar...

Страница 6: ...ATION REQUIREMENTS 11 2 1 INSTALLATION POSITION 11 2 2 CABLES INSTALLATION AND FIXING 12 2 3 3 MENU INTRODUCTION 14 PASSAGE SETTINGS 14 3 1 3 1 1 GATE SYSTEM SETTINGS 14 3 1 2 GATE FUNCTION SETTINGS 1...

Страница 7: ...sitively recognizing a user s valid access card or fingerprint its barriers swing automatically thus allowing users passage to the secured side Chassis Design and Dimensions 1 1 The SBTL9000 Series co...

Страница 8: ...SBTL9000 Series User Manual P a g e 7 Copyright 2021 ZKTECO CO LTD All rights reserved Figure 1 1...

Страница 9: ...ays the pedestrian passage path and directs them to pass through the lane in a safe and orderly manner Alarm The alarm gives an alarm voice if the system detects any unauthorized entry to the passage...

Страница 10: ...m To make the product more versatile this system provides multiple working modes for the user including Normal working mode Normally open mode Normally close mode and Testing mode Normal Working Mode...

Страница 11: ...rights reserved Dimension with Packing mm L 1850 W 400 H 1130 Cabinet Material Aluminium Alloy Lid Material Aluminium Alloy Barrier Material Acrylic Barrier Movement Swing Emergency Mode Supports Sec...

Страница 12: ...check if the connection is done correctly at the connecting points of the ground wire at the connector assemblies and wiring points of the circuits as well as at each movable part of the swing barrie...

Страница 13: ...and its master and slave are connected by an 8 core cable signal and a 2 core cable power When installing the swing barrier turnstile the user only needs to connect it to the corresponding ports Note...

Страница 14: ...anchor bolts or expansion bolts Place the swing barrier turnstile according to the sizes and positions as shown in the figure before installation and fixing Connect the online cables and perform the...

Страница 15: ...tting to set the Gate System These functions are available in Gate System Settings Motor Driver Board Type The motor drive type is automatically matched and subitems cannot be modified as an informati...

Страница 16: ...evice and the valid value is 1 to 65535 Ambient Light Settings Control the blue LED light on the gate Offline Using Enable or disable offline using as per the requirement Clear Running Times Clears al...

Страница 17: ...n an unauthorized way and the clutch is locked automatically It can be set as Automatic release or Authorized release Anti pinch Area Setting If a person object is detected in the anti pinch area the...

Страница 18: ...e refers to the period of time from opening to closing once the turnstile receives an open signal You can set the unattended time or Open Duration Time with a valid value of 2 to 60 seconds Gate Closi...

Страница 19: ...r Clear the alarm counter 3 1 3 External Device Information You can enable disable the direction infrared function to manage the external devices States Description ON When enable it will display the...

Страница 20: ...erminal 3 2 Reset USB Slot Ethernet POE Interface Antenna AUX IN 24V DC Power Supply Wiegand Reader 1 RS 485 EXT RS485 Status Indicator Exit or entry status indicator 12V DC Power Supply FACP_SIGNAL S...

Страница 21: ...SBTL9000 Series User Manual P a g e 20 Copyright 2021 ZKTECO CO LTD All rights reserved...

Страница 22: ...evice IP address and Gateway Note The IP address should be able to communicate with the ZKBioSecurity server preferably in the same network segment with the server address 2 On the Main Menu interface...

Страница 23: ...rights reserved 5 LCD Screen Settings The display of the LCD screen can be set through ZKBioSecurity software including the import replacement of playing videos delete or replace the page background a...

Страница 24: ...erved Click Entrance Control Device Management Device Device Control to set the LCD screen Set the LCD Screen Display 5 1 To set the LCD screen display take the pixel 360 1920 as a template You can se...

Страница 25: ...ideo area occupies 1 3 of the entire LCD screen B Area It is used for setting the count display The counting icon is in jpg format and the count area occupies 2 9 of the entire LCD screen C Area It is...

Страница 26: ...mooth movement Power Supply Maintenance 6 3 Switch off the power supply before maintenance Check the power plug connection if found loose fix it properly Do not change any connection position randomly...

Страница 27: ...the 8 core 2 core connection line 3 Delay in barrier opening or it doesn t close Cause It may be due to if the time of the barrier opening is set as too long Solution Check whether the time of the op...

Страница 28: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved...

Отзывы: