M12
Concrete
Anchor
Power Line
φ
25mm PVC pipe
1019.15
1225.00
120.50
2274.02
2174.02
900
800
592
4
4.
Place the swing barrier turnstile according to the sizes and positions as shown in the figure before
installation and fixing.
For the outlets of the concealed cables, please refer the below diagram indicating the mounting
holes. The input voltage for this swing barrier turnstile is AC100V-120V/200V-240V and its master
and slave are connected by an 2-core cable (signal) and a 2-core cable (power). When installing the
swing barrier turnstile, the user only needs to connect it to the corresponding ports. Note that the
PVC conduits are laid 100mm under the ground, with the height of the exposed part not exceeding
100mm. In addition, the conduit outlet is bent back to prevent the ingress of water into the conduit.
5.
SBT2000S series installation holes and cabling positions is shown in Figure 4-3:
Air Switch
Figure 4-3