5
6
Lock Relay Connection
1)
Device not sharing power with
the lock
NC Lock
DC12V
DC12V
2)
Device sharing power with
the lock
+
12V
GND
FR107
FR107
NC Lock
GND
NO1
COM1
NC1
AUX1
SEN1
BUT1
AL-
AL+
DC12V
+
12V
GND
7
Door Sensor, Exit Button, Alarm and Auxiliary Connection
Lock Power
GND
NO1
COM1
NC1
AUX1
SEN1
BUT1
AL-
AL+
The system supports both
Normally Opened Lock
and
Normally Closed Lock
. The
NO Lock
(normally opened when powered) is connected with ‘
NO
’ and ‘
COM
’ terminals, and the
NC Lock
(normally closed when powered) is connected with ‘
NC
’ and ‘
COM’
terminals. The power can be
shared with the lock or can be used separately for the lock, as shown in the example with
NC Lock
below:
GND
NO1
COM1
NC1
AUX1
SEN1
BUT1
AL-
AL+
BELL-
BELL+
NO
COM
Smoke
Detector
-
+
Detector
Power
Door
Sensor
Exit
Button
Alarm
+
-
Alarm Power
+
-