background image

ProMA Series

User Manual

P a g e

|

8

Copyright©2022 ZKTECO CO., LTD. All rights reserved.

Recommended Standing Posture and Facial Expression

Standing Posture

Facial Expression

Note:

Please keep your facial expression and standing posture natural while enrolment or verification.

1.3

Face Registration

Try to keep the face in the centre of the screen during registration. Please face towards the camera and
stay still during face registration. The screen should look like this:

Содержание ProMA Series

Страница 1: ...ank you for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual ar...

Страница 2: ...the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equipm...

Страница 3: ...ine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible i in case the machine unit equipment...

Страница 4: ...biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhance...

Страница 5: ...tion Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are sep...

Страница 6: ...2 5 2 LOCK RELAY CONNECTION 15 2 5 3 DOOR SENSOR EXIT BUTTON ALARM AND AUXILIARY CONNECTION 16 2 5 4 WIEGAND CONNECTION 16 2 5 5 RS485 CONNECTION 17 2 5 6 ETHERNET CONNECTION 17 3 INSTALLATION 18 3 1...

Страница 7: ...MANAGEMENT 45 10 1 DEVICE MANAGEMENT 45 10 2 UPDATA FIRMWARE 46 10 3 CHANGE PASSWORD 47 10 4 OPERATION LOG 48 10 5 DOWNLOAD FIRMWARE LOGS 49 11 49 11 SYSTEM INFORMATION 50 12 CONNECT TO ZKBIO CVSECURI...

Страница 8: ...the phone screen to the device QR code scanner Note Place your phone within 15 to 50cm of the device distance depends on the size of the phone screen do not block the device QR code scanner and QR cod...

Страница 9: ...n Standing Posture Facial Expression Note Please keep your facial expression and standing posture natural while enrolment or verification 1 3 Face Registration Try to keep the face in the centre of th...

Страница 10: ...es with and without glasses Recommendation for authenticating a face Ensure that the face appears inside the guideline displayed on the screen of the device If the glasses have been changed authentica...

Страница 11: ...P a g e 10 Copyright 2022 ZKTECO CO LTD All rights reserved 2 Appearance 2 1 ProMA QR No Description 1 Microphone 2 Camera 3 2 Display Screen 4 Card Reading Area 5 Doorbell Button 6 Flash 7 QR Code S...

Страница 12: ...Manual P a g e 11 Copyright 2022 ZKTECO CO LTD All rights reserved 2 2 ProMA No Description 1 Microphone 2 Camera 3 2 Display Screen 4 Card Reading Area 5 Doorbell Button 6 Flash 7 Fingerprint Sensor...

Страница 13: ...ies User Manual P a g e 12 Copyright 2022 ZKTECO CO LTD All rights reserved 2 3 ProMA RF No Description 1 Microphone 2 Camera 3 2 Display Screen 4 Card Reading Area 5 Doorbell Button 6 Flash 7 Speaker...

Страница 14: ...Series User Manual P a g e 13 Copyright 2022 ZKTECO CO LTD All rights reserved 2 4 Terminal and Wiring Description 2 4 1 Terminal Description Interface Description 12V 12V Power In GND GND NO1 Lock CO...

Страница 15: ...ight 2022 ZKTECO CO LTD All rights reserved AUX1 Auxiliary Input SEN1 Sensor BUT1 Exit Button AL Alarm AL BELL Bell BELL 12V OUT Power Out GND WD1 OUT Wiegand Out WD0 OUT 485B RS485 485A IWD1 Wiegand...

Страница 16: ...power supply with higher current ratings 2 5 2 Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock The NO Lock normally opened when powered is connected with...

Страница 17: ...or Exit Button Alarm and Auxiliary Connection 2 5 4 Wiegand Connection The Wiegand card reader connects to the top 4 pins of the Wiegand terminal and the last two pins are used by the Access Controlle...

Страница 18: ...multiple readers to the device RS485 can be connected to the terminal as shown in the figure below 2 5 6 Ethernet Connection Connect the device and computer software over an Ethernet cable An example...

Страница 19: ...s for installation 3 2 Device Installation ProMA series installations are the same the following is an example of ProMA 1 Attach the mounting template sticker to the wall and drill holes according to...

Страница 20: ...ProMA Series User Manual P a g e 19 Copyright 2022 ZKTECO CO LTD All rights reserved...

Страница 21: ...built in IP address which can be used for device communication connection to WebServer and ZKBio CVSecurity software etc Note The device uses a 2 display screen which does not support touch operation...

Страница 22: ...the ZKBioSecurity App and a QR code will appear which includes employee ID and card number static QR code only includes card number information The QR code can replace a physical card on a specific d...

Страница 23: ...a with all the card number data registered in the device The following is the card verification screen 5 4 Fingerprint Verification This method compares the fingerprint of the user that is being press...

Страница 24: ...eters of the device 1 Press and hold the Doorbell Button of the device until the IP pops up 2 Open a browser to enter the address to log in to the WebServer the address is https Serial IP Address 1443...

Страница 25: ...he default account is admin password admin 123 Note 1 After logging in for the first time users need to change their original password and log in again before they can use it please refer to 10 3 Chan...

Страница 26: ...Password Method 1 When there is a super admin If you forgot the password of WebServer you can reset it by the registered super admin The detailed steps are as follows 1 Click the icon on the login int...

Страница 27: ...All rights reserved 3 After a successful reset enter the default account and password account admin password admin 123 on the login interface to log in 4 For security reasons please change your passwo...

Страница 28: ...information of the super admin click Save and New 3 Click Access Device Control Synchronize All Data to Devices to synchronize all the data to the device including the new users Note For other specifi...

Страница 29: ...tion Click All Users on the WebServer In this interface you can register the User ID Name Rights Password Card Number and Access Control Role of the new user click Confirm to save Function Name Descri...

Страница 30: ...ard number the user can swipe the card for verification Access Control Role The Access Control Role sets the door access privilege for each user new users will be added to Group 1 by default which can...

Страница 31: ...isplay the fingerprint registration interface in real time press your finger onto the fingerprint sensor of the device and follow the instructions to complete the registration For fingerprint pressing...

Страница 32: ...ready then the Duplicated Face message shows up The registration interface is as follows Note While registering a face the system automatically captures a picture as the profile photo If you do not re...

Страница 33: ...e WebServer click the search bar to enter the required retrieval keyword where the keyword may be the user ID surname or full name and the system will search for the related user information 8 3 Edit...

Страница 34: ...rmation is the same as that of adding a new user except that the User ID cannot be modified The process in detail refers to 8 1 User Registration 8 4 Delete User On the All Users interface select the...

Страница 35: ...ddress is 192 168 1 201 It can be modified according to network availability Subnet Mask The default Subnet Mask is 255 255 255 0 It can be modified according to network availability Gateway The Defau...

Страница 36: ...r Address Once this function is enabled the domain name mode http will be used such as http www XYZ com while XYZ denotes the domain name when this mode is turned ON Disable Domain Name Server Address...

Страница 37: ...LTD All rights reserved 9 3 Date Setup ClickDateSetupontheWebServer Click Manual to manually set the date and time and click Confirm to save Select Open or Close the Daylight Saving Mode function If o...

Страница 38: ...ID Masking When enabled and then the user is successfully compared and verified the User ID in the displayed verification result will be replaced with an to achieve secure protection of sensitive pri...

Страница 39: ...85 is used as the function of the Master unit it can be connected to a card reader DM10 Communicate with the device through the DM10 serial port Baudrate There are 5 baudrate options at which the data...

Страница 40: ...n the acquired facial image and all registered facial templates is greater than the set value The valid value ranges from 0 to 100 The higher the thresholds the lower the misjudgment rate the higher t...

Страница 41: ...comparison If a face s rotation angle exceeds this set value it will be filtered by the algorithm i e ignored by the terminal thus no registration and comparison interface will be triggered Image Qual...

Страница 42: ...poofing Using NIR Using near infrared spectra imaging to identify and prevent fake photos and video attacks Binocular Live Detection Threshold Facilitates to judge whether the captured visible image i...

Страница 43: ...testwhetherthefunctionsofvariousmodulesareworkingnormally 9 7 1 Test Face Click Test Mode the ProMA device will display the Test Face interface in real time click End of Testing to exit the test After...

Страница 44: ...rights reserved 9 7 2 Test Fingerprint Sensor ClickStart the ProMA device will display the Test Fingerprint interface in real time click End to exit the test 9 8 Wiegand Setup ClickWiegandSetupon the...

Страница 45: ...2 ZKTECO CO LTD All rights reserved Function Name Description Wiegand Format Its value can be 26 bits 34 bits 36 bits 37 bits 50 bits and 60 bits Wiegand Bits The number of bits of the Wiegand data ID...

Страница 46: ...ser Restart Choose whether to restart the device Close SSH SSH is used to enter the background of the device for maintenance choose whether to close the SSH Reset The Reset function restores the devic...

Страница 47: ...nd attendance logs access records of all registered users 10 2 Updata Firmware ClickUpdataFirmwareontheWebServer Select an upgrade file and click Confirm to complete firmware upgrade operation Note If...

Страница 48: ...Series User Manual P a g e 47 Copyright 2022 ZKTECO CO LTD All rights reserved 10 3 Change Password ClickChangePasswordontheWebServer Inthisinterface youcanchangethepasswordandresetthepasswordofWebSe...

Страница 49: ...a g e 48 Copyright 2022 ZKTECO CO LTD All rights reserved 10 4 Operation Log ClickOperationLogon theWebServer All the user s operation records on the device or WebServer are saved Users can search and...

Страница 50: ...Series User Manual P a g e 49 Copyright 2022 ZKTECO CO LTD All rights reserved 10 5 Download Firmware Logs ClickOperationLogon theWebServer Inthisinterface youcanselectdownloadthemain biometric ordev...

Страница 51: ...l P a g e 50 Copyright 2022 ZKTECO CO LTD All rights reserved 11 System Information ClickSystemInformationontheWebServer In this interface you can view the data capacity device and firmware informatio...

Страница 52: ...ion MAC address fingerprint and face algorithm version information platform and manufacturer information Device Capacity Displays the current device s user storage password fingerprint card and face s...

Страница 53: ...IP address and gateway of the device Note The IP address should be able to communicate with the ZKBio CVSecurity server preferably in the same network segment with the server address 2 In the WebServ...

Страница 54: ...unication Monitor to set the ADMS Service Port as shown in the figure below 12 2 Add Device on the Software Add the device by searching The process is as follows 1 Click Access Device Search to open t...

Страница 55: ...ile Credential After downloading and installing the App the user needs to set the Server before login The steps are given below 1 In ZKBio CVSecurity System System Management Parameters set Enable QR...

Страница 56: ...the login screen tap Server Setting and type the IP Address or the Domain Name of the Server and its Port Number 4 Tap the QR Code icon to scan the QR code of the new App client After the client is id...

Страница 57: ...oyee to switch to Employee Login screen Enter the Employee ID and Password Default 123456 to login 6 Tap Mobile Credential on the App and a QR code will appear which includes employee ID and card numb...

Страница 58: ...s function for the first time the App will prompt to authorize the modification of screen brightness settings as shown in the figure The QR code refreshes automatically for every 30s and supports manu...

Страница 59: ...for registration 4 Please show your face and forehead and do not cover your face and eyebrows with your hair 5 The digital photo should be straight edged colored and half portrayed with only one pers...

Страница 60: ...light For persons with thick eyeglasses frame it is recommended to capture two images one with eyeglasses and the other one without the eyeglasses Face Complete face with clear contour real scale eve...

Страница 61: ...sult of your use of services 1 User Registration Information At your first registration the feature template Fingerprint template Face template Palm template will be saved on the device according to t...

Страница 62: ...for access control the product will enable the prompt tone of the camera Once you enable this function we assume that you are aware of the potential security risks 5 All the data collected by our pro...

Страница 63: ...nt Name Hazardous Toxic Substance Element Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr6 Polybrominated Biphenyls PBB Polybrominated Diphenyl Ethers PBDE Chip Resistor Chip Capacitor Chip Induc...

Страница 64: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2022 ZKTECO CO LTD All Rights Reserved...

Отзывы: