This ProlD series reader needs to be connected to a host machine in order to
transmit card information via RS-485 or wiegand. The following is an example
of the connection to InBio Series controller.
Connect the controller via RS485
#2
TCP/IP
PC
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
Router
#1
#6
DC12V
DC12V
#7
RS-485A
RS-485B
GND
+12V
ON
KE
1 2 3 4
ON
KE
1 2 3 4
ON
KE
1 2 3 4
ON
KE
1 2 3 4
Notes:
7
1. A maximum of seven readers can be connected to one controller.
2. Before connecting RS-485 readers, open the rear panel of the reader and set
the RS-485 address of the reader via DIP switch according to the connection
of each reader.
3. If the RS-485 communication wire is longer than
100
meters, it is needed to
set the 4th DIP switch of the last reader to
ON
state.
4. The DIP switch needs to be set with the controller powered off and takes
effect after restart. After setting, the DIP switch does not need to be set
back to its original position.
6.
Controller Connection