LB330 Parking Barrier
User Manual
P a g e
|
1 5
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Main control Board Operation
6.3.1
Self-inspection Learning Switch Barrier Limit Method:
1.
Long press the "key" of the control board for 2 seconds after it begins normally ("190"
is displayed). The main board display value decreases as the barrier moves in the
direction of closing the gate. The main board display returns to "190" when the motor
reaches the closing limit, and the closing self-check is completed.
2.
Press and hold the "On" button on the main board for 2 seconds after the shutdown
self-check is done. The display value on the main board increases as the gate moves in
the gate opening direction. The main board buzzer beeps for a long time when the
motor reaches its open limit. The self-check for the opening is now complete, and the
gate can be used normally.
6.3.2
Operation Steps of the Main Board Buttons:
1.
Press and hold the main board menu button until L-1 is appearing.
2.
To select the menu directory, press the "On" or "Close" key on the mainboard. If you
need to enter this directory, press the "Menu" key on the mainboard once.
3.
if you need to modify a catalogue parameter, after accessing the menu catalogue, hit
the "No" and "Off" keys to increase or decrease this menu parameter, once the
alteration is complete, if you need to change other catalogue parameters, click the
"Menu" key once to return to the previous menu catalogue. Return to the main menu
and proceed with the second step. If you do not alter any other settings, you may save
and exit the menu by pressing the "Confirm" key on the mainboard.