background image

6 FBL6000 Pro series installation guide

4 Menu Operation

Menu

There are four keys on the control panel, including "UP", "DOWN", "ENT", and "ESC". Press “ENT” to

modify settings, press "UP" and "DOWN" button to select a function, and press ”ESC” to exit.

The menu has the following options:

1. Passing mode

Two-way swipe (default)
Left free, Right swipe
Left swipe, Right free
Two-way free
Left prohibit, Right swipe
Left swipe, Right prohibit
Left prohibit, Right free
Left free, Right prohibit
Two-way prohibit

2. Opening speed

Low speed
Medium speed (default)
High speed

3. Closing speed

Low speed
Medium speed (default)
High speed

4. Volume setting

Volume: off
The value ranges from 1 to 16 (default 5).
1 is the minimum value; 16 is the maximum value.

5. Opening duration

After the gate is opened, it will be automatically closed if no one passes through within a certain
duration. The default value is 10 seconds. The value ranges from 5 to 60.

6. Reset the counter

Out counter
Into the counter
All (default)

Содержание FBL6000 Pro Series

Страница 1: ...Pro series Applicable Model s FBL1000 Pro series FBL1200 Pro series FBL2000 Pro series FBL2200 Pro series FBL4000 Pro series FBL4200 Pro series FBL5000 Pro series FBL5200 Pro series FBL6000 Pro series...

Страница 2: ...dard three core power extension wire M12 expansion screw included in the package 3 Thread the wires through the insulation tube before laying them underground 4 Power wire and signal wire should be ke...

Страница 3: ...evice Note that a ground cable must be connected 2 Wait 30 seconds till the wing gate completes the self test procedure 3 Start the air switch inside the wing gate to check whether the wing gate funct...

Страница 4: ...e location of device installation Decide the installation location based on the space needed as illustrated in Figure 3 1A and Figure 3 1B Figure 3 1A Single Passage Wing Gate Figure 3 1B Dual Passage...

Страница 5: ...ding to installation hole positions see Figure 3 2 for installation hole positions The unit of the figures in the drawings is mm Figure 3 2 e Apply screw glue to the outer surface and threads of the e...

Страница 6: ...Pro series installation guide 5 Figure 3 3 5 Card Swiping Warning Lines It is recommended that a warning line is set to prompt users to swipe cards outside the warning lines as shown in Figure 3 4 Fig...

Страница 7: ...swipe Left swipe Right prohibit Left prohibit Right free Left free Right prohibit Two way prohibit 2 Opening speed Low speed Medium speed default High speed 3 Closing speed Low speed Medium speed defa...

Страница 8: ...Audio alarm only default Disable the alarm function 11 Set fire signal Enable default Disable 12 Exchange voice of door opening Yes No default 13 Speed compensation of master machine Compensation val...

Страница 9: ...8 FBL6000 Pro series installation guide 5 Wiring Diagram Below is the wiring diagram Figure 5 1...

Страница 10: ...es installation guide 9 Copyright 2019 ZKTECO CO LTD All rights reserved ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394...

Отзывы: