F18 User Manual V1.0
- 46 -
will trigger the alarm signal as illegal access.
Out: New user’s first time access will pass.
In anti-passback mode not restrict of IN.
In-Out anti-passback (APB-Out/In):
New user’s first time access will pass. Only user’s last record is
out-record, can the door be open when he/she want IN. Otherwise it will
trigger the alarm signal as illegal access. Only user’s last record is
in-record, can the door be open when he/she want out. Otherwise it will
trigger the alarm signal as illegal access.
None anti-passback:
Slave machine can verify to open the door, and the prompt “no enrolled
data” on the master machine.
Anti-passback function is available.
Machine status:
Press
/ to move cursor to the item to be set. If select “Control Out”,
the master control out, the other machine control entry. Need two
machines cooperation.
Содержание F18