RS-485 readers and Wiegand readers need to be connected with the master elevator controller in
order to make relevant settings through the ZKBio CVSecurity Software. The system sends the
personnel information to the master controller through the software, and reader then uploads the
data to the master controller for comparison and verification after collection. The following is the
wiring diagram of various readers and elevator controller.
Default IP address: 192.168.
1
.201
Subnet mask: 255.255.255.0
IP address: 192.168.
1
.160
Subnet mask: 255.255.255.0
DC12V
EC16 Elevator Controller
TCP/IP
ZKBio CVSecurity
FR1500
KR600
RS-485
Wiegand
3.
Each EC16 can connect a maximum of eight RS-485 readers and two Wiegand readers.
1.
The readers can be connected to the elevator controller via Wiegand and RS-485.
2.
Open DEMO, select the serial port number, the default baud rate is 115200, click "
Connect
" and
"
Scan Address
" and then put the card or QR code (paper, electronic , mobile phone) into the
recognition range of the card reader, and read the card. The device automatically obtains
and transmits the information carried by the card or QR code to the controller.
Note:
7
QR600-VK
Wiegand
485A
485B
GND
+12V
DC12V
DC12V
#1
#2
#7
#8
RS-485A
RS-485B
GND
Multiple readers are connected to the controller
Reader Connection