Cautions

Please note the following cautions. Mis-operation may lead to personal injury or equipment 
failure:

1.  Do not energize the system before installation is complete; never carry out installation activities when 

the system is energized.  

2.  All peripheral devices must be grounded.
3.  The conduits of wires under relay must be matched with metaled conduits, other wires can use PVC 

conduits.

4.  It is strongly recommended that the length of exposed part of any connection cable should not be 

longer than 4 mm. Professional clamping tools may be used to avoid unintentional contact of exposed 
wires to avoid short-circuit or communication failure.

5.  It is recommended that card readers and buttons be installed at height of 1.4m-1.5m above ground.
6.  It is recommended to use the power supply for control panel, and external power supply for each lock.
7.  The appliance shall be installed and wired in accordance with national electrical code and by qualified 

personnel only.

Description of normal working state:

Connect the system to the power supply. If the system works properly, the POWER indicator (red) is lit 
constantly. 

2

 

Control Panel Indicators

When the C2-260 is powered on, normally the 

POWER

 indicator (red) is lit constantly, the 

RUN

 indicator 

(green) shall flash slowly (indicating the system is normal), and other indicators are all off. 

COMM

 indicator (yellow): It flashes when the system is communicating with other devices (e.g., PC). When 

the indicator is flashing continuously, it indicates data transmission. When the indicator is flashing slowly, 
it indicates real-time monitoring status.

Содержание C2-260

Страница 1: ...ation Guide C2 260 Metal Cabinet Version 1 0 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this...

Страница 2: ...ttons be installed at height of 1 4m 1 5m above ground 6 It is recommended to use the power supply for control panel and external power supply for each lock 7 The appliance shall be installed and wire...

Страница 3: ...2 Product Dimension 3 C2 260 Aux485 WR485 C2 260 Metal Cabinet 330 0mm 364 6mm 75 7mm...

Страница 4: ...Cabinet 4 C2 260 Panel Heat Dissipation Hole Aux485 Power Supply Cable Conduit Power Indicator Punch Hole for cables Mounting Holes We recommend drilling the mounting plate screws into solid wood i e...

Страница 5: ...4 5 Internal Wiring Diagram C2 260 Power Indicator Aux485 Power Supply L N G V V B B 12V Battery Prepared by the user...

Страница 6: ...be connected externally to RS485 reader 4 Restore factory setting The NO 4 of DIP switch is OFF by default When it is moved up and down for three times within 5 seconds and nally returned to OFF posi...

Страница 7: ...AUX4 DC12V AUX485 12V GND 485B 485A AUX1 GND AUX2 AUX3 GND AUX4 DC12V 485A 485B GND Notes 1 A C2 260 can connect to maximum two AUX485 modules 2 Each AUX485 module can connect to maximum four auxilia...

Страница 8: ...ote 1 It s recommended to connect maximum four readers to one C2 260 2 A single RS485 reader interface can supply a maximum of 750 mA 12V current So the entire current consumption should be less than...

Страница 9: ...8 Exit Button Connection 9 EXIT GND BUT K2S Exit Button...

Страница 10: ...nd the NC Lock Normally Closed when powered is connected with NC and COM terminals The power can be shared with the lock or can be used separately for the lock as shown in the example with NC Lock bel...

Страница 11: ......

Отзывы: