background image

               

                                                                               

http://www.zketech.com 

 

                                                     

EBD-A20H User Manual      

                     Copyright (C) 2006-2017 ZKETECH 

1. Features 

1.1 Battery Capacity Test 

This  tester  is  designed  for  discharging  of  a  wide  range  of  batteries,  including  NiMH,  NiCd, 
LiPo, LiFe and Pb, as well as the capacity test.   

1.2 Portable Power Bank Test 

This tester supports charging and discharging of portable power banks, as well as capacity test. 

1.3 Power Performance Test 

This tester supports performance and aging tests of various kinds of DC power supplies.   

2. Specifications 

1) Power Supply: DC 12V/1A   

2) Voltage Range: 0-30.00V, stepper 0.01V 

3) Current Range: 0.10-20.00A, stepper 0.01A (current adjusted automatically according to the 
power limits) 

4) Discharging mode: 

DSC-CC: Discharging batteries at a constant current, support testing battery capacity or current 
of power supplies. 

DSC-CP : Discharging batteries at  a constant    power, for constant power equipment-like use 
or testing power. 

5) Voltage accuracy: between 0-4.5V, 0.003V, 

±

0.5%, between 4.5-30V, 0.01V, 

±

0.5%. 

6) Current accuracy: 0.20-20.00A, 0.01A, 

±

0.5%. 

7) Capacity detection: < 10Ah,0.001AH; 10-100Ah,0.01Ah; > 100Ah,0.1Ah 

8) Discharging power: continuous rating is 180W and instantaneous power could reach 200W 

9) Four lines: voltage and current channels separated for high test accuracy 

10) LCD Display: voltage, current, time, capacity, power, energy, and etc 

11) PC Connection: the tester can connect to a computer through a designated USB-TTL cable 
(with  areial  socket)  for  more  functions,  like  graphs,  calibration,  firmware  upgrade,  and  test 
circulation. 

 

 

 

 

 

   

Содержание EBD-A20H

Страница 1: ...ZKETECH Release Date 2017 01 01 Multifunction Electronic Load EBD A20H ...

Страница 2: ... to the power limits 4 Discharging mode DSC CC Discharging batteries at a constant current support testing battery capacity or current of power supplies DSC CP Discharging batteries at a constant power for constant power equipment like use or testing power 5 Voltage accuracy between 0 4 5V 0 003V 0 5 between 4 5 30V 0 01V 0 5 6 Current accuracy 0 20 20 00A 0 01A 0 5 7 Capacity detection 10Ah 0 001...

Страница 3: ... 4 Display and setting 4 1 Buttons SET setting knob rotate to left right and press ON start 4 2 Testing interface The first line shows testing mode CC CP voltage and current Testing modes include CC in this mode the tester supports discharging at a constant current It allows you to set discharging current and cut off voltage Discharge stops when voltage in tests reaches below cut off voltage Disch...

Страница 4: ...ou can move it to the option you want to change One press on the SET knob to move one step to right Rotate SET to left and right to change the parameter The parameter will change automatically if it exceeds limitation Press the ON button to switch to next setting option After completes settings press SET knob for a long time to save data and return to the upper level interface In the testing inter...

Страница 5: ...ys use the tester within the allowed range 3 PC connection software EB Tester Software download it from www zketech com 4 PC connection follow EB Tester Software User Manual 5 Technical support zke2006 163 com 6 Taobao store zke2006 taobao com We always focus on innovation and improvement and will keep upgrading the software Please frequently visit www zketech com to download the latest manuals ...

Отзывы: