First line: mode and power setting. 

Second line: cut-off voltage (testing automatically stops when voltage reaches below this value) 
the maximum testing time setting (no time limit if being set 0). 

3) CHG-CV (constant voltage-current charge) 

 

First line: mode and current setting. 

Second line: constant voltage, cut-off current (testing automatically stops when current reaches 
below this value; can be set above 0.1A), and the auto mode setting: 

—

 

NOR      —— normal mode

testing stops when charging finish. 

—

 

AUTO    —— automatically go through the “charge-discharge-charge” round test. 

Put the cursor on AUTO and a long-time press on the “ON” button can lead to the setting of 
auto discharging parameters:   

 

The  first  parameter  is  discharging  current,  and  the  second  the  cut-off  voltage,  the  third  is  the 
waiting time for step switches (you are suggested  to  wait  for  5-10  minutes  between  charging 
and discharging for the battery cooling).   

After you finish setting, press the “SET” button for a long time to return to the previous setting 
interface. 

Press “SET” button for a long time in the first-level setting interface to save data and go back 
to testing interface.   

After finish setting, press “ON” button to start testing. 

4.4 Setting examples 

1) Discharge setting (discharge the Lithium battery from 3.7V to 2.8V at 5A) 

 

2)  Charge  setting  (charge  the  Lithium  battery  from  3.7V  to  4.2V  at  2.5A,  cut-off  current  is 
0.11A) 

 

 

 

 

Содержание EBC-A40L

Страница 1: ...ZKETECH Release Date 2017 01 01 EBC A40L Battery Tester User Manual ...

Страница 2: ...n 5V at a large current the maximum current it supports is 35A in charging and 40A in discharging 2 Specifications 3 Connecting pattern 3 1 Testing connector 3 2 PC connection The EBC A40L tester can connect with a computer through a designated USB TTL cable 3 3 Power supply AC 200V 4 Display and setting 4 1 Buttons SET 1 setting knob ON 2 start and stop ...

Страница 3: ... Press the ON button to start discharging test shows DSC and one more press to stop shows OFF You can open setting interface by press on the SET button for 2 seconds in the stop state This function is invalid when the tester being connected with the PC software 4 3 Setting interface The cursor default is on mode setting Press SET button to move it to the value you want to set up Spin the SET knob ...

Страница 4: ... test Put the cursor on AUTO and a long time press on the ON button can lead to the setting of auto discharging parameters The first parameter is discharging current and the second the cut off voltage the third is the waiting time for step switches you are suggested to wait for 5 10 minutes between charging and discharging for the battery cooling After you finish setting press the SET button for a...

Страница 5: ...not be reversed 2 Always use the tester within the allowed range 3 PC connection software EB Tester Software download it from www zketech com 4 PC connection follow EB Tester Software User Manual 5 Technical support zke2006 163 com 6 Taobao store zke2006 taobao com We always focus on innovation and improvement and will keep upgrading the software Please frequently visit our official website www zk...

Отзывы: