User Manual V1.1
28
After the device is restored to factory defaults, the device information is
restored to factory defaults, including the device number, system
password, IP address, 485 address, and keyboard password.
Note:
The user information stored on device will not be cleared after
the device is restored to factory defaults.
3.3 Access Control Function
Access control setting is to set user’s open door time zone, control lock
and related device’s parameters.
To unlock, the enrolled user must accord with the following conditions:
1. The current unlock time should be in the effective time of user time
zone or group zone.
2. The group where user is must be in access control (or in the same
access control with other group, to open the door together).
The system default the new enrolled user as the first group, default group
time zone as 1, access control as the first group, and the new enrolled
user is in unlock (User can modify the related setting of access control,
through access control software).
Notice:
The device access control function need to set and modify
through the access control software, for detail, please refer to the
software user manual.
Access Control Function:
1. Access Control Time Zone:
Time zone is the minimum unit of access control option. The whole
system can define 50 time zones. Every time zone defines seven time
sections (namely, a week). Every time section is the effective time zone
within 24 hours everyday. Every user can set 3 time zones. “or” exists
Содержание MA300