background image

ZR4ST-3 SURVEY KIT

USER GUIDE

CONVENTIONAL WIRELESS COMMUNICATOR

CH 1                 CH 2                      CH 1                 CH 2

POWER/

CHARGE

TX

RX

RSSI/dB

START

LOCAL - REMOTE

REMOTE - LOCAL

SURVEYOR

DEVICE

LOCAL - REMOTE

PASS / FAIL

SIGNAL QUALITY %

REMOTE - LOCAL

BATTERY

TSD256 (Iss 6)                                                           

                                                                                                                                                                                                    

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание ZR4ST-3

Страница 1: ...WIRELESS COMMUNICATOR CH 1 CH 2 CH 1 CH 2 POWER CHARGE TX RX RSSI dB START LOCAL REMOTE REMOTE LOCAL SURVEYOR DEVICE LOCAL REMOTE PASS FAIL SIGNAL QUALITY REMOTE LOCAL BATTERY TSD256 Iss 6 www acornf...

Страница 2: ...n RLM Survey Objectives 11 Typical Ziton RLM System Overview 11 Ziton RLM Survey Guidelines 11 13 Step By Step Guide Ziton System Survey 14 Ziton RLM Survey Form 15 Ziton Hub RCC Survey 16 Ziton Hub R...

Страница 3: ...Start www acornfiresecurity com www acornfiresecurity com...

Страница 4: ...um signal headroom must be checked to ensure reliable communication This is essential to ensure immunity against site attenuation caused by environmental changes and other electrical equipment The sur...

Страница 5: ...About The Survey Kit www acornfiresecurity com www acornfiresecurity com...

Страница 6: ...RCC surveys Signal Surveyor 1 per kit This part of the survey equipment is used to communicate with the Device Survey Tool This unit will be located in the position of the proposed Hub RCC or RLM Devi...

Страница 7: ...d interference level To achieve the maximum signal distance the background level should be as low as possible This level is shown between 000 and 100 If the background levels are high try repositionin...

Страница 8: ...The device Survey Tool requires 4 x AA LR6 Alkaline 1 5V batteries Please ensure batteries are installed in the correct polarity as shown above Signal Surveyor Battery Replacement The Signal Surveyor...

Страница 9: ...ress the rear switch to initiate a signal After a few seconds results will be displayed and a high pass or a flat fail tone will be heard LED signal indication is also shown on the device a Green LED...

Страница 10: ...RLM Survey www acornfiresecurity com www acornfiresecurity com...

Страница 11: ...dio Detector Base PRESS HERE TO LOG ON IDENT POWER FAULT LOOP INTERFACE ISOLATOR ACTIVE SUPPLY TEST DISABLE FAULT ALARM SOUNDER DELAY SOUNDER FAULT DISABLED SUPPLY FAULT EARTH FAULT LOW BATTERY SYSTEM...

Страница 12: ...are allowed Max 2 RLMs per loop POWER FAULT LOOP INTERFACE ISOLATOR ACTIVE SUPPLY TEST DISABLE FAULT ALARM SOUNDER DELAY SOUNDER FAULT DISABLED SUPPLY FAULT EARTH FAULT LOW BATTERY SYSTEM FAULT SOUND...

Страница 13: ...ing as much 360 degree coverage as possible 5 Remember the RLMs can each accommodate a maximum of 31 wireless devices Max 31 devices per RLM www emsgroup co uk Radio Detector Base PRESS HERE TO LOG ON...

Страница 14: ...p 2 Turn on the Signal Surveyor Step 3 Record the background level displayed for future reference Refer to the Using the Signal Surveyor section for more information Step 4 Turn on the Device Survey T...

Страница 15: ...Site Customer name Survey date Company Surveyor name RLM number Background Level Device No Signal Level Pass Fail Comments 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 2...

Страница 16: ...Hub RCC Survey www acornfiresecurity com www acornfiresecurity com...

Страница 17: ...etector Base PRESS HERE TO LOG ON IDENT POWER FAULT SUPPLY TEST DISABLE FAULT ALARM SOUNDER DELAY SOUNDER FAULT SUPPLY FAULT EARTH FAULT LOW BATTERY SYSTEM FAULT SOUNDER START STOP PANEL SILENCE RESET...

Страница 18: ...rol Panel Radio Hub RCC RCC Pass RCC Pass Max 31 RCCs RCC www emsgroup co uk Radio Detector Base PRESS HERE TO LOG ON IDENT POWER FAULT SUPPLY TEST DISABLE FAULT ALARM SOUNDER DELAY SOUNDER FAULT SUPP...

Страница 19: ...ackground level displayed for future reference Refer to the Using the Signal Surveyor section for more information Step 4 Turn on the Device Survey Tool Step 5 Position the Device Survey Tool against...

Страница 20: ...Comms Path Talks to Hub dB Pass Fail Signal Level Background Level RCC Location Comms Path Talks to dB Pass Fail Signal Level Background Level 31 31 100 98 7 7 Main Corridor 1 RCC Location Comms Path...

Страница 21: ...C Location Comms Path Talks to dB Pass Fail Signal Level Background Level RCC Location Comms Path Talks to dB Pass Fail Signal Level Background Level RCC Location Comms Path Talks to dB Pass Fail Sign...

Страница 22: ...ice Survey Tool against the wall or ceiling in the positions of the proposed Wireless device Step 11 Record the signal level Step 12 Repeat Steps 10 11 for all device positions associated with the RCC...

Страница 23: ...Survey Form RCC number Additional notes Device No Signal Level Pass Fail Comments 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 dB www acornfiresecurity com www a...